ISO 18090-1:2026

International Standard   Current Edition · Approved on 26 May 2026

Radiological protection — Characteristics of reference pulsed radiation — Part 1: Photon radiation

ISO 18090-1:2026 Files

English 17 Pages
Current Edition
OMR 48.17

ISO 18090-1:2026 Scope

This document is directly applicable to pulsed X-radiation with pulse duration of 0,1 ms up to 10 s. This range covers the whole range used in medical diagnostics at the time of publication. Some specifications can also be applicable for much shorter pulses; one example is the air kerma of one pulse. Such a pulse can be produced, e.g. by X-ray flash units or high-intensity femtosecond-lasers. Other specifications are not applicable for much shorter pulses; one example is the time-dependent behaviour of the air kerma rate. This cannot be measurable for technical reasons as no suitable instrument is available, e.g. for pulses produced by a femtosecond-laser.

This document specifies the characteristics of reference pulsed radiation for calibrating and testing radiation protection dosemeters and dose rate meters with respect to their response to pulsed radiation. At this point, it is only concerned with the characteristics of single pulses. Single pulses are the most difficult for dosemeters to measure. Determining the dose for repeated pulses is easier, but still more difficult than for continuous radiation, i.e. the performance of the dosemeters when measuring repeated pulses lies between these extremes. The radiation characteristics includes the following:

  1. time-dependent behaviour of the air kerma rate of the pulse;
  2. time-dependent behaviour of the X-ray tube high voltage during the pulse;
  3. uniformity of the air kerma rate within a cross-sectional area of the radiation beam;
  4. air kerma of one radiation pulse;
  5. air kerma rate of the radiation pulse;
  6. repetition frequency.

This document does not define new radiation qualities but uses those radiation qualities specified in existing ISO and IEC standards. Instead, this document gives the link between the parameters for pulsed radiation and the parameters for continuous radiation specifying the radiation qualities. It does not specify specific values or series of values for the pulsed radiation field but specifies only those limits for the relevant pulsed radiation parameters that are required for calibrating dosemeters and dose rate meters and for determining their response depending on the said parameters.

The pulse parameters with respect to the phantom-related quantities were determined using conversion coefficients according to ISO 4037 (all parts). This is possible as the radiation qualities specified in existing ISO and IEC standards are used.

A given reference pulsed X-ray facility is characterized by the parameter ranges over which the full specifications and requirements according to this document are met. Therefore, not all reference pulsed X-ray facilities can produce pulses covering the same parameter ranges.

Best Sellers

GSO 150-2:2013
 
Gulf Standard
Expiration dates for food products - Part 2 : Voluntary expiration dates
OS GSO 150-2:2013
GSO 150-2:2013 
Omani Standard
Expiration dates for food products - Part 2 : Voluntary expiration dates
OS GSO 9:2022
GSO 9:2022 
Omani Standard
Labeling of prepackaged food stuffs
GSO 9:2022
 
Gulf Technical Regulation
Labeling of prepackaged food stuffs

Recently Published

ISO 24131-4:2026
 
International Standard
Internal protection by polymeric lining for ductile iron pipes — Requirements and test methods — Part 4: Ceramic epoxy lining
ISO 23611-1:2026
 
International Standard
Soil quality — Sampling of soil invertebrates — Part 1: Hand-sorting and extraction of earthworms
ISO 24829:2026
 
International Standard
Plastics — Polyether polyols and polymer polyols — Determination of aldehydes and ketones
ISO 12480-5:2026
 
International Standard
Cranes — Safe use — Part 5: Bridge and gantry cranes