GSO ISO 13253:2021

ISO 13253:2017
Gulf Standard   Current Edition · Approved on 01 July 2021

Ducted air-conditioners and air-to-air heat pumps — Testing and rating for performance

GSO ISO 13253:2021 Files

GSO ISO 13253:2021 Scope

ISO 13253:2017 specifies performance testing, the standard conditions and the test methods for determining the capacity and efficiency ratings of air-cooled, air-conditioners and air-to-air heat pumps.

ISO 13253:2017 is applicable to the following equipment:

- ducted air-cooled air conditioners and ducted air to air heat pumps.

ISO 13253:2017 is limited to

- residential, commercial and industrial single-package, and split-system air conditioners and heat pumps,

- factory-made, electrically driven and use mechanical compression,

- utilizing single, multiple and variable capacity components, and

- multiple split-system utilizing one or more refrigeration systems, one outdoor unit and one or more indoor units, controlled by a single thermostat/controller.

The requirements of testing and rating contained in this document are based on the use of matched assemblies.

ISO 13253:2017 is not applicable to the rating and testing of the following:

a) water-source heat pumps or water-cooled air-conditioners;

b) multi-split-system air-conditioners and air-to-air heat pumps (see ISO 15042 for testing of such equipment);

c) mobile (windowless) units having a condenser exhaust duct;

d) individual assemblies not constituting a complete refrigeration system;

e) equipment using the absorption refrigeration cycle;

f) non-ducted equipment (see ISO 5151 for testing of such equipment);

g) ducted air conditioners and/or ducted heat pumps, rated at less than 8 kW and intended to operate at external static pressures of less than 25 Pa, controlled by a single thermostat/controller (refer to ISO 5151).

ISO 13253:2017 does not cover the determination of seasonal efficiencies, which can be required in some countries because they provide a better indication of efficiency under actual operating conditions.

NOTE Throughout this document, the terms "equipment" and "systems" mean "air-conditioners" and/or "heat pumps".

Best Sellers From Electrical Sector

GSO 2530:2016
 
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
OS GSO 2530:2016
GSO 2530:2016 
Omani Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
OS GSO 34:2007
GSO 34:2007 
Omani Standard
LEAD-ACID STARTER BATTERIES USED FOR MOTOR VEHICLES AND INTERNAL COMBUSTION ENGINES
GSO 34:2007
 
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR MOTOR VEHICLES AND INTERNAL COMBUSTION ENGINES

Recently Published from Electrical Sector

GSO 2770:2024
 
Gulf Standard
WATER HEATERS - ENERGY PERFORMANCE REQUIREMENTS
GSO IEC 61558-2-2:2024
IEC 61558-2-2:2022 
Gulf Standard
Safety of transformers, reactors, power supply units and combinations thereof - Part 2-2: Particular requirements and tests for control transformers and power supply units incorporating control transformers
GSO IEC 60664-1:2024
IEC 60664-1:2020 
Gulf Standard
Insulation coordination for equipment within low-voltage supply systems - Part 1: Principles, requirements and tests
GSO IEC 61936-2:2024
IEC 61936-2:2023 
Gulf Standard
Power installations exceeding 1 kV AC and 1,5 kV DC - Part 2: DC