GSO IEC 61526:2015 Scope

This International Standard applies to personal dose equivalent meters with the following characteristics: a) They are worn on the trunk or the extremities of the body. b) They measure the personal dose equivalents Hp(10) and Hp(0,07) from external X and gamma, neutron and beta radiations, and may measure the personal dose equivalent rates H& p () 10 and H& p ( ) 0,07 . c) They have a digital indication. d) They may have alarm functions for the personal dose equivalents or personal dose equivalent rates. This standard is therefore applicable to the measurement of the following combinations of dose quantities (including the respective dose rates) and radiation 1) Hp(10) and Hp(0,07) from X and gamma radiations; 2) Hp(10) and Hp(0,07) from X, gamma and beta radiations; 3) Hp(10) from X and gamma radiations; 4) Hp(10) from neutron radiations; 5) Hp(10) from X, gamma and neutron radiations; 6) Hp(0,07) from X, gamma and beta radiations. NOTE 1 When reference is made in this standard to ”dose”, this is meant to indicate personal dose equivalent, unless otherwise stated. NOTE 2 When reference is made in this standard to ”dosemeter”, this is meant to include all personal dose equivalent meters, unless otherwise stated. This standard specifies requirements for the dosemeter and, if supplied, for its associated readout system. This standard specifies, for the dosemeters described above, general characteristics, general test procedures, radiation characteristics as well as electrical, mechanical, safety and environmental characteristics. The only requirements specified for associated readout systems are those which affect its accuracy of readout of the personal dose equivalent and alarm settings and those which concern the influence of the reader on the dosemeter. This standard also specifies in Annex C usage categories with respect to different measuring capabilities. This standard does not cover special requirements for accident or emergency dosimetry although the dosemeters may be used for this purpose. The standard does not apply to dosemeters used for measurement of pulsed radiation, such as radiation emanating from most medical diagnostic X-ray facilities, linear accelerators or similar equipment.

Best Sellers From Electrical Sector

GSO 2530:2016
 
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
OS GSO 2530:2016
GSO 2530:2016 
Omani Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
OS GSO 34:2007
GSO 34:2007 
Omani Standard
LEAD-ACID STARTER BATTERIES USED FOR MOTOR VEHICLES AND INTERNAL COMBUSTION ENGINES
GSO 34:2007
 
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR MOTOR VEHICLES AND INTERNAL COMBUSTION ENGINES

Recently Published from Electrical Sector

GSO IEC 61643-41:2026
IEC 61643-41:2025 
Gulf Standard
Low-voltage surge protective devices - Part 41: Surge protective devices connected to DC low-voltage power systems – Requirements and test methods
GSO IEC 60704-2-3:2026
IEC 60704-2-3:2025 
Gulf Standard
Household and similar electrical appliances - Test code for the determination of airborne acoustical noise - Part 2-3: Particular requirements for dishwashers
GSO IEC 60270:2026
IEC 60270:2025 
Gulf Standard
High-voltage test techniques – Charge-based measurement of partial discharges
GSO IEC PAS 63629:2026
IEC PAS 63629:2025 
Gulf Standard
PSR – Specific rules for luminaires