GSO IEC 61031:2014
IEC 61031:1990
Gulf Standard
Current Edition
· Approved on 25 December 2014
Design, location and application criteria for installed area gamma radiation dose rate monitoring equipment for use in nuclear power plants during normal operation and anticipated operational occurrences
Adoption by Endorsement!
This document is to indicate the endorsement of
IEC 61031:1990
Auto Update!
Adoption by endorsement for the latest version of this international/national standard and the previous adopted edition remains effective for 2 years starting from the date of last international update.
GSO IEC 61031:2014 Files
English 21 Pages
Current Edition
Reference Language
Obtaining this standard through the store is currently unavailable. You can acquire it directly from its source.
GSO IEC 61031:2014 Scope
This International Standard applies to the design, location and application of installed equipment for monitoring local gamma radiation dose rates within nuclear power plants during normal operation and anticipated operational occurrences. High range area gamma radiation dose rate monitoring equipment for accident conditions currently addressed by IEC 951-3 is not within the scope of this standard.
This standard is intended to be used in conjunction with IEC 532 (second edition)*.
NOTE - This standard does not apply to the measurement of neutron dose rate. Additional equipment for neutron monitoring may be required, depending on the plant design, if the neutron dose rate makes a substantial contribution to the total dose equivalent to personnel.
This standard provides guidelines for the design principles, the location, the application, the calibration, the operation, and the testing of installed equipment for continuously monitoring local gamma radiation dose rates in nuclear power plants under normal operation conditions and anticipated operational occurrences. These instruments are normally referred to as area radiation monitors.
Radiation monitors utilized in area radiation monitoring equipment are dealt with IEC 532. As discussed in that standard, measurement of gamma radiation may be expressed by a number of alternative quantities depending on national regulations. However, for this type of instrument, the most likely quantity to be measured is the absorbed dose in air (Gy), or the ambient dose equivalent (Sv).
Best Sellers From Electrical Sector
GSO 2530:2016
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners

OS GSO 2530:2016
GSO 2530:2016
Omani Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners


OS GSO 34:2007
GSO 34:2007
Omani Standard
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES


GSO 34:2007
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES

Recently Published from Electrical Sector
GSO 31:1984
Gulf Standard
METHODS OF TEST FOR
PVC-INSULATED CABLES AND CORDS
WITH CIRCULAR COPPER CONDUCTORS

GSO 195:1994
Gulf Standard
METHODS OF TEST FOR
ADHESIVE INSULATING TAPES FOR
ELECTRICAL PURPOSES

OS GSO 195:1994
GSO 195:1994
Omani Standard
METHODS OF TEST FOR
ADHESIVE INSULATING TAPES FOR
ELECTRICAL PURPOSES


GSO 723:1997
Gulf Standard
Methods of test for telephone sets.