OS GSO IEC 62682:2017 Scope
1.1 General applicability
This International Standard specifies general principles and processes for the lifecycle management of alarm systems based on programmable electronic controller and computerbased human-machine interface (HMI) technology for facilities in the process industries. It covers all alarms presented to the operator, which includes alarms from basic process control systems, annunciator panels, safety instrumented systems, fire and gas systems, and
emergency response systems.
The practices in this standard are applicable to continuous, batch, and discrete processes.
There can be differences in implementation to meet the specific needs based on process type.
In jurisdictions where the governing authorities (e.g., national, federal, state, province, county, city) have established process safety design, process safety management, or other requirements, in addition to the requirements of this standard, these should be taken into consideration.
The primary function within the alarm system is to notify operators of abnormal process conditions or equipment malfunctions and support the response. The alarm systems can include both the basic process control system (BPCS) and the safety instrumented system (SIS), each of which uses measurements of process conditions and logic to generate alarms.
Figure 1 illustrates the concepts of alarm and response dataflow through the alarm system.The alarm system also includes a mechanism for communicating the alarm information to the operator via an HMI, usually a computer screen or an annunciator panel. Additional functions of the alarm system are an alarm and event log, an alarm historian, and the generation of performance metrics for the alarm system. There are external systems that can use the data from the alarm system.
1.2 Exclusions and inclusions
1.2.1 Operators
The functions of the operator receiving and responding to alarms are included in the scope of this standard. Management of operators is excluded from the scope of this standard.
1.2.2 Process sensors and final control elements
The alarms from sensors and final control elements are included in the scope of this standard.
Process sensors and final control elements are shown in Figure 1 to indicate alarms can be implemented in these devices. The design and management of process sensors and final control elements are excluded from the scope of this standard.
1.2.3 Safety instrumented systems
The alarms from safety instrumented systems are included in the scope of this standard. The safety instrumented system (SIS) is shown in Figure 1 to indicate alarms can be implemented in these devices. The design and management of safety instrumented systems are excluded from this standard. Refer to IEC 61511.
The alarms and diagnostics from fire detection and protective systems or security systems that are presented to the operator through the control system are included in the scope of this standard. Fire detection and protective systems and security systems are excluded from the scope of this standard.
1.2.4 Event data
The indication and processing of analog, discrete, and event data other than alarm indications are excluded from the scope of this standard. The analysis techniques using both alarm and event data are excluded from the scope of this standard.
1.2.5 Alarm identification methods
Required methods of alarm identification are not specified in this standard. Examples of alarm identification methods are listed.
1.2.6 Management of change
A specific management of change procedure is not included in this standard. Some requirements and recommendations for a management of change procedure are included.
Best Sellers From Electrical Sector
GSO 2530:2016
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
OS GSO 2530:2016
GSO 2530:2016
Omani Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
OS GSO 34:2007
GSO 34:2007
Omani Standard
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
GSO 34:2007
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
Recently Published from Electrical Sector
GSO IEC 60704-2-18:2024
IEC 60704-2-18:2022
Gulf Standard
Household and similar electrical appliances - Test code for the determination of airborne acoustical noise - Part 2-18: Particular requirements for electric water heaters
GSO IEC 60079-11:2024
IEC 60079-11:2023
Gulf Standard
Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
GSO IEC 61076-2-116:2024
IEC 61076-2-116:2022
Gulf Standard
Connectors for electrical and electronic equipment - Product requirements - Part 2 -116: Detail specification for circular connectors size 15 with up to 3+PE power contacts and auxiliary contacts, with bayonet-locking.
GSO IEC 61076-2-115:2024
IEC 61076-2-115:2023
Gulf Standard
Connectors for electrical and electronic equipment - Product requirements - Part 2-115: Circular connectors - Detail specification for 12-pole shielded connectors with 2 A rated current and IP65/IP67 metal housing with push-pull locking