OS GSO ISO 6144:2008

ISO 6144:2003
Omani Standard   Current Edition · Approved on 20 February 2008

Gas analysis - Preparation of Calibration gas mixtures - Static Volumetric method

OS GSO ISO 6144:2008 Files

Arabic 36 Pages
Current Edition
OMR 83.81
English 29 Pages
Current Edition Reference Language
OMR 73.62

OS GSO ISO 6144:2008 Scope

This International Standard specifies a method for the preparation of calibration gas mixtures by a static volumetric method and provides a procedure for calculating the volumetric composition of the mixture. It can be used either with binary gas mixtures (containing one calibration component in a complementary gas, which is usually nitrogen or air[1, 2]) or with mixtures containing more than one component in the complementary gas. This International Standard also specifies how the expanded uncertainty in the volume fraction of each calibration component in the mixture is determined by a rigorous evaluation of all the measurement uncertainties involved, including those associated with the apparatus used for the preparation of the gas mixture and those associated with the experimental procedure itself. NOTE 1 This International Standard is generally applicable to the preparation of calibration gas mixtures containing calibration components in the concentration range 10 × 10?9 (10 ppb — parts per billion) to 50 × 10?6 (50 ppm — parts per million) by volume. However, gas mixtures may be prepared at larger or smaller volume fractions, provided that the components used in the static dilution process are selected appropriately. NOTE 2 A relative expanded uncertainty of not greater than ± 1 % at a level of confidence of 95 % may be achievable at these concentrations, provided that: ? the purities of the parent gases have been determined by analysis and any significant impurities and the uncertainties in their measured concentrations have been taken into account; ? no significant adsorption effects or chemical reactions occur between the gaseous constituents and the internal surfaces of the apparatus, and there are no reactions between any of the gaseous components, i.e. between the calibration component and complementary gas or between the calibration components themselves; ? all the relevant apparatus used in the preparation of a calibration gas mixture have been calibrated with assigned measurement uncertainties which are appropriate to calculating the final expanded uncertainty for the calibration gas mixture prepared.

Best Sellers From Metrology Sector

OS GSO OIML R87:2021
OIML R87:2016 
Omani Standard
Quantity of product in prepackages
GSO OIML R87:2021
OIML R87:2016 
Gulf Standard
Quantity of product in prepackages
GSO OIML R79:2021
OIML R79:2015 
Gulf Standard
Labeling requirements for prepackages
OS GSO OIML R79:2021
OIML R79:2015 
Omani Standard
Labeling requirements for prepackages

Recently Published from Metrology Sector

GSO ISO 10713:2026
ISO 10713:2025 
Gulf Standard
Jewellery and precious metals — Gold alloy coatings
GSO ISO 20816-2:2026
ISO 20816-2:2017 
Gulf Standard
Mechanical vibration — Measurement and evaluation of machine vibration — Part 2: Land-based gas turbines, steam turbines and generators in excess of 40 MW, with fluid-film bearings and rated speeds of 1 500 r/min, 1 800 r/min, 3 000 r/min and 3 600 r/min
GSO ISO 23783-2:2026
ISO 23783-2:2022 
Gulf Standard
Automated liquid handling systems — Part 2: Measurement procedures for the determination of volumetric performance
GSO ISO 16610-45:2026
ISO 16610-45:2025 
Gulf Standard
Geometrical product specifications (GPS) — Filtration — Part 45: Morphological profile filters: Segmentation