ISO 27186:2026

مواصفة قياسية دولية   الإصدار الحالي · اعتمدت بتاريخ ٢٣ يوليو ٢٠٢٦

Active implantable medical devices — Four-pole connector system for implantable cardiac rhythm management devices — Dimensional and test requirements

ملفات الوثيقة ISO 27186:2026

الإنجليزية 107 صفحات
الإصدار الحالي
OMR 108.03

مجال الوثيقة ISO 27186:2026

This document specifies a four-pole connector system for implantable cardiac rhythm management (CRM) devices that have electrogram sensing and pacing functions with or without defibrillation capability. This document includes requirements for the connector portion of an implantable lead and for the mating connector cavity attached to an implantable pulse generator. Key dimensions and performance requirements are specified together with appropriate test methods.

This document establishes two types of connector assembly with their configurations, which are not intended to be interchangeable:

  • a high-voltage connector: a connector that can have either
  • two low-voltage contacts combined with one or two high-voltage contacts, or
  • only two high-voltage contacts;
  • a “low-voltage only connector”: a connector that has either three or four low-voltage contacts.

This document specifies a dimensional lockout feature that prevents the low-voltage contacts of the lead connectors from contacting the high-voltage contacts of high-voltage connector cavities.

This document does not replace or provide alternatives for unipolar or bipolar connector International Standards that currently exist (such as ISO 11318[2] and ISO 5841-3[1]).

This document is not applicable to high-voltage systems with intended outputs greater than 1 000 V or systems with an electric flow greater than 50 A.

This document is not applicable to systems which include sensors or unique electrodes that are not capable of conventional pacing electrogram sensing or defibrillation functions.

This document does not specify all connector features and it does not address all aspects of functional compatibility, safety or reliability of leads and pulse generators assembled into a system.

This document does not include requirements for accessories or adaptors used with four-pole connectors. Refer to Annex P for more information on connector-related products.

NOTE 1        The safety, reliability, biocompatibility, biostability and function of any particular part are the responsibility of the manufacturer.

NOTE 2        Lead and pulse generator connector systems not conforming to this document can be safe and reliable and can have clinical advantages.

الأكثر مبيعاً

GSO 150-2:2013
 
مواصفة قياسية خليجية
فترات صلاحية المنتجات الغذائية - الجزء الثاني : فترات الصلاحية الاختيارية
OS GSO 150-2:2013
GSO 150-2:2013 
مواصفة قياسية عمانية
فترات صلاحية المنتجات الغذائية - الجزء الثاني : فترات الصلاحية الاختيارية
OS GSO 9:2022
GSO 9:2022 
مواصفة قياسية عمانية
بطاقات المواد الغذائية المعبأة
GSO 9:2022
 
لائحة فنية خليجية
بطاقات المواد الغذائية المعبأة

اعتمدت مؤخراً

ISO 5183-1:2026
 
مواصفة قياسية دولية
Resistance welding equipment — Electrode adaptors, male taper 1:10 — Part 1: Conical fixing, taper 1:10
ISO 21384-3:2026
 
مواصفة قياسية دولية
Uncrewed aircraft systems — Part 3: Operational procedures
ISO 10993-3:2026
 
مواصفة قياسية دولية
Biological evaluation of medical devices — Part 3: Evaluation of genotoxicity, carcinogenicity, reproductive toxicity and developmental toxicity
ISO 20457:2026
 
مواصفة قياسية دولية
Plastics moulded parts — Tolerances and acceptance conditions