ISO/TS 21569-7:2022

International Standard   Current Edition · Approved on 05 December 2022

Horizontal methods for molecular biomarker analysis — Methods of analysis for the detection of genetically modified organisms and derived products — Part 7: Real-time PCR based methods for the detection of CaMV and Agrobacterium Ti-plasmid derived DNA sequences

ISO/TS 21569-7:2022 Files

English 12 Pages
Current Edition
OMR 32.7

ISO/TS 21569-7:2022 Scope

This document specifies a procedure for the detection of a DNA sequence of the open reading frame five (ORF V) from cauliflower mosaic virus (CaMV) and a procedure for the detection of the DNA sequence of the nopaline synthase (nos) gene from tumour-inducing (Ti) plasmids of phytopathogenic Rhizobium radiobacter (formerly named Agrobacterium tumefaciens). The procedures can be used in the context of screening for genetically modified crop/plants and their derived products to further clarify a positive PCR result for a specific promoter or terminator of CaMV (P-35S, T-35S), or both, and the nos gene (P-nos, T-nos), respectively.

The methods specified in this document will detect and identify naturally occurring CaMV or Rhizobium radiobacter (Ti plasmid) DNA, or both, if present in the sample in the absence of a genetically modified plant event containing the specified target sequences.

Both methods are based on the real-time polymerase chain reaction (PCR) and are applicable for the analysis of DNA extracted from foodstuffs and other products such as feedstuffs and seeds/grains. The application of the methods requires the extraction of an adequate amount of amplifiable DNA from the relevant matrix.

With appropriate calibration material, the CaMV ORF V or nos copy number, or both, can be estimated and compared, respectively, with the estimated copy number for the promoter (P-35S, P-nos) or the terminator (T-35S, T-nos) sequences, or both. Thereby, conclusions are possible about the presence of an unknown genetically modified organism (GMO) in addition to any detected CaMV DNA or Rhizobium radiobacter Ti plasmid DNA, or both, in a test sample.

Best Sellers

GSO 150-2:2013
 
Gulf Standard
Expiration dates for food products - Part 2 : Voluntary expiration dates
OS GSO 150-2:2013
GSO 150-2:2013 
Omani Standard
Expiration dates for food products - Part 2 : Voluntary expiration dates
OS GSO 9:2022
GSO 9:2022 
Omani Standard
Labeling of prepackaged food stuffs
GSO 9:2022
 
Gulf Technical Regulation
Labeling of prepackaged food stuffs

Recently Published

ISO/TR 13849-3:2026
 
International Standard
Safety of machinery — Safety-related parts of control systems — Part 3: Markov model-based PFH calculation
ISO/TS 23099:2026
 
International Standard
Large yachts — A methodologic framework to assess large yachts (30m+) on their environmental performance and credentials
ISO 11783-3:2026
 
International Standard
Tractors and machinery for agriculture and forestry — Serial control and communications data network — Part 3: Application layer, transport layer and network layer
ISO 13914:2026
 
International Standard
Soil, treated biowaste and sludge — Determination of dioxins and furans and dioxin-like polychlorinated biphenyls by gas chromatography with mass selective detection (high resolution mass spectrometry, HRMS, and tandem mass spectrometry, MS/MS)