ISO/TS 12869-2:2024 Scope

This document provides the guidelines, minimum requirements and performance characteristics intended to guarantee that manufactured systems intended for on-site/field use (i.e. outside the laboratory) provide reliable and reproducible results.

This document specifies the requirements for technologies that enable on-site detection and quantification of Legionella spp. and L. pneumophila using a quantitative polymerase chain reaction assay (qPCR). It specifies general methodological requirements, performance evaluation requirements and quality control requirements. This document is intended to be used by manufacturers of these technologies so that they produce detection systems that end users can operate safely and effectively. End users will be guided by this document to adhere to manufacturer’s instructions, to ensure user competency and to perform the necessary controls.

Technical details specified in this document are given for information only. Any other technical solutions complying with the performance requirements are suitable.

NOTE          For validation and performance requirements, see Clause 9.

This document is intended to be applied in the bacteriological investigation of all types of water (hot or cold water, cooling tower water, etc.), unless the nature and/or content of suspended matter and/or background microorganisms interfere with the determination. This interference can result in an adverse effect on both the detection limit and the quantification limit.

The results are expressed as the number of genome units of Legionella spp. and/or L. pneumophila per millilitre (or litre) of sample.

Although the method described in this document is applicable to all types of water, some additives, such as chemicals used for water treatment, can interfere with and/or affect the sensitivity of the method.

The qPCR methods do not give any information about the physiological state of the Legionella. However, there are on-site qPCR methodologies which are able to distinguish intact bacteria from free DNA.

Best Sellers

GSO 150-2:2013
 
Gulf Standard
Expiration dates for food products - Part 2 : Voluntary expiration dates
OS GSO 150-2:2013
GSO 150-2:2013 
Omani Standard
Expiration dates for food products - Part 2 : Voluntary expiration dates
OS GSO 9:2022
GSO 9:2022 
Omani Standard
Labeling of prepackaged food stuffs
GSO 9:2022
 
Gulf Technical Regulation
Labeling of prepackaged food stuffs

Recently Published

ISO 17947-1:2026
 
International Standard
Fine ceramics (advanced ceramics, advanced technical ceramics) — Methods for chemical analysis of silicon nitride powders — Part 1: Wet chemical methods, X-ray fluorescence (XRF) using the fused cast-bead method, carrier-gas hot extraction (CGHE) and combustion methods
ISO/IEC 5181:2026
 
International Standard
Information security, cybersecurity and privacy protection — Data provenance
ISO 4240-3:2026
 
International Standard
Fine bubble technology — Environmental applications — Part 3: Test method for on-site evaluation of the performance of algae bloom removal facilities
ISO 17966:2026
 
International Standard
Assistive products for toileting, bathing and showering — Requirements and test methods