GSO EN 1634-2:2024

EN 1634-2:2008
Gulf Standard   Current Edition · Approved on 14 October 2024

Fire resistance and smoke control tests for door, shutter and openable window assemblies and elements of building hardware - Part 2: Fire resistance characterisation test for elements of building hardware

GSO EN 1634-2:2024 Files

GSO EN 1634-2:2024 Scope

This European Standard specifies a method for characterizing the influence on fire performance of items of building hardware for incorporation into hinged or pivoted vertically installed fire door assemblies (having either one or two leaves) or vertically installed openable window assemblies, of known fire resistance of up to and including 240 minutes integrity (and where relevant insulation) in accordance with EN 1634-1. It applies to the testing of building hardware for use on hinged and pivoted doors and openable windows which include framed glazed doors and windows, but not glass doors. It does not include a test for durability or other performance characteristics, which should be evaluated according to the product standard for the item of building hardware or as given in EN 14600. The method is suitable for characterizing building hardware for use on non-metallic door or window assemblies consisting of cellulosic materials or mineral boards faced with cellulosic materials, hung in either cellulosic, mineral cored or metal frames: or conventional steel doors made from sheet steel, not more than 1,5 mm thick, hung in steel frames (steel doors include doors filled with mineral board or mineral fibre cores but not steel clad timber/cellulosic doors). The size of these assemblies can be up to that given in the field of direct application for the door leaf construction concerned. This method is not directly appropriate for evaluating building hardware for use on glass or glazed doors with decorative perimeter framing. The appropriateness of this method of test can be established by reference to the flow chart given in Annex A. This European Standard does not constitute a fire resistance test for a leaf, window, frame, intumescent seal, or anything other than the selected item of building hardware. The use of any resulting field of direct application is restricted to leaf and frame constructions which have been successfully tested to EN 1634-1.

Best Sellers From Construction and Building Sector

GSO 1431:2002
 
Gulf Technical Regulation
Sanitary appliances - pressurized flushing devices
OS GSO 1431:2002
GSO 1431:2002 
Omani Standard
Sanitary appliances - pressurized flushing devices
GSO 1427:2008
 
Gulf Standard
Ceramic Sanitary Appliances - Western Water Closets
OS GSO 1427:2008
GSO 1427:2008 
Omani Standard
Ceramic Sanitary Appliances - Western Water Closets

Recently Published from Construction and Building Sector

GSO ISO 6781-1:2024
ISO 6781-1:2023 
Gulf Standard
Performance of buildings — Detection of heat, air and moisture irregularities in buildings by infrared methods — Part 1: General procedures
GSO ISO 19467-2:2024
ISO 19467-2:2021 
Gulf Standard
Thermal Performance of windows and doors — Determination of solar heat gain coefficient using solar simulator — Part 2: Centre of glazing
GSO EN 13501-5:2024
EN 13501-5:2016 
Gulf Standard
Fire classification of construction products and building elements - Part 5: Classification using data from external fire exposure to roofs tests
GSO ASTM C1527/C1527M:2024
ASTM C1527/C1527M:23 
Gulf Standard
Standard Specification for Travertine Dimension Stone