GSO IEC 60383-1:2024
IEC 60383-1:2023
Gulf Standard
Current Edition
·
Approved on
14 October 2024
Insulators for overhead lines with a nominal voltage above 1000 V - Part 1: Ceramic or glass insulator units for a.c. systems - Definitions, test methods and acceptance criteria
GSO IEC 60383-1:2024 Files
No files are available for this standard right now!
GSO IEC 60383-1:2024 Scope
IEC 60383-1:2023 applies to insulators of ceramic material or glass for use on AC overhead power lines and overhead traction lines with a nominal voltage greater than 1 000 V and a frequency not greater than 100 Hz. It also applies to insulators for use on DC overhead electric traction lines. This document applies to string insulator units, rigid overhead line insulators and to insulators of similar design when used in substations. lt does not apply to insulators forming parts of electrical apparatus or to parts used in their construction or to post insulators which are covered by IEC 60168, Tests on indoor and outdoor post insulators of ceramic material or glass for systems with nominal voltages greater than 1 000 V.
The object of this document is:
- to define the terms used
- to define insulator characteristics and to prescribe the conditions under which the specified values of these characteristics shall be verified
- to prescribe test methods
- to prescribe acceptance criteria.
This fifth edition cancels and replaces the fourth edition published in 1993. This edition includes the following significant technical changes with respect to the previous edition:
a) The layout of the document has been changed in order to increase readability;
b) RIV test has been added (Clause 14);
c) Impulse puncture test in air has been added (15.2);
d) Residual strength test has been added (Clause 21);
e) Zinc sleeve test has been added (Clause 28);
f) Impact test has been added (Clause 30);
g) Annex C, coatings on ceramic and glass insulators has been added;
h) Annex D, impact test has been added.
The object of this document is:
- to define the terms used
- to define insulator characteristics and to prescribe the conditions under which the specified values of these characteristics shall be verified
- to prescribe test methods
- to prescribe acceptance criteria.
This fifth edition cancels and replaces the fourth edition published in 1993. This edition includes the following significant technical changes with respect to the previous edition:
a) The layout of the document has been changed in order to increase readability;
b) RIV test has been added (Clause 14);
c) Impulse puncture test in air has been added (15.2);
d) Residual strength test has been added (Clause 21);
e) Zinc sleeve test has been added (Clause 28);
f) Impact test has been added (Clause 30);
g) Annex C, coatings on ceramic and glass insulators has been added;
h) Annex D, impact test has been added.
Best Sellers From Electrical Sector
GSO 2530:2016
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
OS GSO 2530:2016
GSO 2530:2016
Omani Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
OS GSO 34:2007
GSO 34:2007
Omani Standard
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
GSO 34:2007
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
Recently Published from Electrical Sector
GSO 2770:2024
Gulf Standard
WATER HEATERS - ENERGY PERFORMANCE REQUIREMENTS
GSO IEC 61558-2-2:2024
IEC 61558-2-2:2022
Gulf Standard
Safety of transformers, reactors, power supply units and combinations thereof - Part 2-2: Particular requirements and tests for control transformers and power supply units incorporating control transformers
GSO IEC 60664-1:2024
IEC 60664-1:2020
Gulf Standard
Insulation coordination for equipment within low-voltage supply systems - Part 1: Principles, requirements and tests
GSO IEC 61936-2:2024
IEC 61936-2:2023
Gulf Standard
Power installations exceeding 1 kV AC and 1,5 kV DC - Part 2: DC