GSO ASTM F1862/F1862M:2022

ASTM F1862/F1862M:17
Gulf Standard   Current Edition · Approved on 12 May 2022

Standard Test Method for Resistance of Medical Face Masks to Penetration by Synthetic Blood (Horizontal Projection of Fixed Volume at a Known Velocity)

GSO ASTM F1862/F1862M:2022 Files

GSO ASTM F1862/F1862M:2022 Scope

1.1 This test method is used to evaluate the resistance of medical face masks to penetration by the impact of a small volume (~2 mL) of a high-velocity stream of synthetic blood. Medical face mask pass/fail determinations are based on visual detection of synthetic blood penetration. 1.2 This test method does not apply to all forms or conditions of blood-borne pathogen exposure. Users of the test method must review modes for face exposure and assess the appropriateness of this test method for their specific application. 1.3 This test method primarily addresses the performance of materials or certain material constructions used in medical face masks. This test method does not address the performance of the medical face mask’s design, construction, or interfaces or other factors with the potential to affect the overall protection offered by the medical face mask and its operation (such as filtration efficiency and pressure drop). Procedures for measuring these properties are contained in Test Method F2101 and MIL-M-36954C. 1.4 This test method does not address breathability of the medical face mask materials or any other properties affecting the ease of breathing through the medical face mask. This test method evaluates medical face masks as an item of protective clothing. This test method does not evaluate the performance of medical face masks for airborne exposure pathways or in the prevention of the penetration of aerosolized body fluids deposited on the medical face mask. 1.5 The values stated in SI units or inch-pound units are to be regarded separately as standard. The pressure values stated in each system are not exact equivalents. However, as the corresponding velocities are within 1 % of each other, (see X1.4.2), reporting of the results in either units is permitted. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Best Sellers From Health Sector

OS GSO 2017:2023
GSO 2017:2023 
Omani Standard
Personal Care and Baby Wet Wipes
GSO 2017:2023
 
Gulf Standard
Personal Care and Baby Wet Wipes
OS GSO 2241:2023
GSO 2241:2023 
Omani Standard
Cosmetic Products - Body Cleaners
GSO 2241:2023
 
Gulf Standard
Cosmetic Products - Body Cleaners

Recently Published from Health Sector

GSO ISO 23217:2025
ISO 23217:2024 
Gulf Standard
Injection systems for self-administration by paediatric patients — Requirements and guidelines for design
GSO ISO/TS 24665:2025
ISO/TS 24665:2023 
Gulf Standard
Playground and recreational areas — Framework for the competence of playground inspectors and playground maintenance technicians
GSO ISO 8536-13:2025
ISO 8536-13:2024 
Gulf Standard
Infusion equipment for medical use — Part 13: Graduated flow regulators for single use with fluid contact
GSO ISO 20611:2025
ISO 20611:2018 
Gulf Standard
Adventure tourism — Good practices for sustainability — Requirements and recommendations