GSO ASTM E1662:2022

ASTM E1662:95a(2018)
Gulf Standard   Current Edition · Approved on 12 May 2022

Standard Classification for Serviceability of an Office Facility for Sound and Visual Environment

GSO ASTM E1662:2022 Files

GSO ASTM E1662:2022 Scope

1.1 This classification covers pairs of scales for classifying an aspect of the serviceability of an office facility, that is, the capability of an office facility to meet certain possible requirements for suitable sound and visual conditions. 1.2 Within that aspect of serviceability, each pair of scales, shown in Figs. 1-6, are for classifying one topic of serviceability. Each paragraph in an Occupant Requirement Scale (see Figs. 1-6) summarizes one level of serviceability on that topic, which occupants might require. The matching entry in the Facility Rating Scale (see Figs. 1-6) is a translation of the requirement into a description of certain features of a facility which, taken in combination, indicate that the facility is likely to meet that level of required serviceability. 1.3 The entries in the Facility Rating Scale (see Figs. 1-6) are indicative and not comprehensive. They are for quick scanning to estimate approximately, quickly, and economically, how well an office facility is likely to meet the needs of one or another type of occupant group over time. The entries are not for measuring, knowing, or evaluating how an office facility is performing. 1.4 This classification can be used to estimate the level of serviceability of an existing facility. It can also be used to estimate the serviceability of a facility that has been planned but not yet built, such as one for which single-line drawings and outline specifications have been prepared. 1.5 This classification indicates what would cause a facility to be rated at a certain level of serviceability but does not state how to conduct a serviceability rating nor how to assign a serviceability score. That information is found in Practice E1334. The scales in this classification are complimentary to and compatible with Practice E1334. Each requires the other

Best Sellers From Construction and Building Sector

GSO 1431:2002
 
Gulf Technical Regulation
Sanitary appliances - pressurized flushing devices
OS GSO 1431:2002
GSO 1431:2002 
Omani Standard
Sanitary appliances - pressurized flushing devices
GSO 1427:2008
 
Gulf Standard
Ceramic Sanitary Appliances - Western Water Closets
OS GSO 1427:2008
GSO 1427:2008 
Omani Standard
Ceramic Sanitary Appliances - Western Water Closets

Recently Published from Construction and Building Sector

GSO ISO 52000-3:2024
ISO 52000-3:2023 
Gulf Standard
Energy performance of buildings — Overarching EPB assessment — Part 3: General principles for determination and reporting of primary energy factors (PEF) and CO2 emission coefficients
GSO EN 1634-3:2024
EN 1634-3:2004 
Gulf Standard
Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elements of building hardware - Part 3: Smoke control test for door and shutter assemblies
GSO ISO/TR 52016-2:2024
ISO/TR 52016-2:2017 
Gulf Standard
Energy performance of buildings — Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads — Part 2: Explanation and justification of ISO 52016-1 and ISO 52017-1
GSO ASTM C1354/C1354M:2024
ASTM C1354/C1354M:22 
Gulf Standard
Standard Test Method for Strength of Individual Stone Anchorages in Dimension Stone