1.1 This practice presents a procedure for calculating the unit weights and water contents of soils containing oversize particles when the data are known for the soil fraction with the oversize particles removed. 1.2 This practice also can be used to calculate the unit weights and water contents of soil fractions when the data are known for the total soil sample containing oversize particles. 1.3 This practice is based on tests performed on soils and soil-rock mixtures in which the portion considered oversize is that fraction of the material retained on the 4.75-mm [No. 4] sieve. Based on these tests, this practice is applicable to soils and soil-rock mixtures in which up to 40 % of the material is retained on the 4.75-mm [No. 4] sieve. The practice also is considered valid when the oversize fraction is that portion retained on some other sieve, but the limiting percentage of oversize particles for which the correction is valid may be lower. However, the practice is considered valid for materials having up to 30 % oversize particles when the oversize fraction is that portion retained on the 19-mm [3⁄4-in.] sieve. 1.4 The factor controlling the maximum permissible percentage of oversize particles is whether interference between the oversize particles affects the unit weight of the finer fraction. For some gradations, this interference may begin to occur at lower percentages of oversize particles, so the limiting percentage must be lower for these materials to avoid inaccuracies in the computed correction. The person or agency using this practice shall determine whether a lower percentage is to be used. 1.5 This practice may be applied to soils with any percentage of oversize particles subject to the limitations given in 1.3 and 1.4. However, the correction may not be of practical significance for soils with only small percentages of oversize particles. The person or agency specifying this practice shall specify a minimum percentage of oversize particles below which the practice need not be applied. If a minimum percentage is not specified, 5 % shall be used.

Best Sellers From Construction and Building Sector

GSO 1431:2002
 
Gulf Technical Regulation
Sanitary appliances - pressurized flushing devices
OS GSO 1431:2002
GSO 1431:2002 
Omani Standard
Sanitary appliances - pressurized flushing devices
GSO 1427:2008
 
Gulf Standard
Ceramic Sanitary Appliances - Western Water Closets
OS GSO 1427:2008
GSO 1427:2008 
Omani Standard
Ceramic Sanitary Appliances - Western Water Closets

Recently Published from Construction and Building Sector

GSO ASTM C1224:2024
ASTM C1224:22 
Gulf Standard
Standard Specification for Reflective Insulation for Building Applications
GSO ASTM E631:2024
ASTM E631:15(2024) 
Gulf Standard
Standard Terminology of Building Constructions
GSO ISO 20760-1:2024
ISO 20760-1:2018 
Gulf Standard
Water reuse in urban areas — Guidelines for centralized water reuse system — Part 1: Design principle of a centralized water reuse system
GSO ISO 52000-3:2024
ISO 52000-3:2023 
Gulf Standard
Energy performance of buildings — Overarching EPB assessment — Part 3: General principles for determination and reporting of primary energy factors (PEF) and CO2 emission coefficients