GSO ASTM E787:2021

ASTM E787:81(2017)
Gulf Standard   Current Edition · Approved on 01 July 2021

Standard Specification for Disposable Glass Micro Blood Collection Pipets

GSO ASTM E787:2021 Files

English 3 Pages
Current Edition Reference Language

GSO ASTM E787:2021 Scope

This specification covers two dimensionally different (short and long) disposable glass micropipets used primarily to collect whole human blood specimens for clinical analysis and testing. Short and long pipets are available as coated with heparin (Type I) or uncoated (Type II).The pipets shall be fabricated from borosilicate glass, Type I, Class B, or soda lime glass, Type II. Heparin shall be the ammonium salt isolated from the lungs or intestinal mucosa of beef or pork origin and shall meet the specified heparin potency. The physical requirements including design, dimensions, workmanship, color coding, capillarity, fluidity, lot or control number, resistance to centrifugal force, and heparin coating are specified. The following tests shall be performed: capillarity test, fluidity test, sheep plasma test, human whole blood test, resistance to centrifugal force test, and heparin content test. The physical requirements for short Caraway pipet and long Natelson pipet are illustrated as well.

Best Sellers From Health Sector

GSO 2017:2023
 
Gulf Standard
Personal Care and Baby Wet Wipes
GSO 2241:2023
 
Gulf Standard
Cosmetic Products - Body Cleaners
GSO 2063:2023
 
Gulf Standard
Cosmetic Products - Hair Conditioner (Balsam)
GSO 1223:2023
 
Gulf Standard
Cosmetic Products-Deodorants

Recently Published from Health Sector

GSO ASTM F2011:2024
ASTM F2011:02(2018) 
Gulf Standard
Standard Specification for Safety and Performance of Fun-Karts
GSO ISO 18113-3:2024
ISO 18113-3:2022 
Gulf Standard
In vitro diagnostic medical devices — Information supplied by the manufacturer (labelling) — Part 3: In vitro diagnostic instruments for professional use
GSO ISO 20776-2:2024
ISO 20776-2:2021 
Gulf Standard
Clinical laboratory testing and in vitro diagnostic test systems — Susceptibility testing of infectious agents and evaluation of performance of antimicrobial susceptibility test devices — Part 2: Evaluation of performance of antimicrobial susceptibility test devices against reference broth micro-dilution
GSO ISO 27186:2024
ISO 27186:2020 
Gulf Standard
Active implantable medical devices — Four-pole connector system for implantable cardiac rhythm management devices — Dimensional and test requirements