GSO IEC 60601-2-1:2021
IEC 60601-2-1:2009
Gulf Standard
Current Edition
·
Approved on
01 July 2021
Medical electrical equipment - Part 2-1: Particular requirements for the basic safety and essential performance of electron accelerators in the range 1 MeV to 50 MeV
GSO IEC 60601-2-1:2021 Files
English
128 Pages
Current Edition
Reference Language
Obtaining this standard through the store is currently unavailable. You can acquire it directly from its source.
GSO IEC 60601-2-1:2021 Scope
IEC 60601-2-1:2009 applies to the basic safety and essential performance of electron accelerators in the range 1 MeV to 50 MeV, used for treatment of patients. This particular standard establishes requirements to be complied with by manufacturers in the design and construction of electron accelerators for use in radiotherapy; it does not attempt to define their optimum performance requirements. Its purpose is to identify those features of design that are regarded, at the present time, as essential for the safe operation of such medical electrical equipment. It places limits on the degradation of medical electrical equipment performance beyond which it can be presumed that a fault condition exists and where an interlock then operates to prevent continued operation of the me equipment. This third edition cancels and replaces the second edition published in 1998 and its Amendment 1 (2002). It constitutes a technical revision. This third edition addresses the following issues not covered in previous editions:
- alignment with the new relevant collateral standards;
- new technologies in radiotherapy, including stereotactic radiosurgery (SRS) and stereotactic radiotherapy (SRT), intensity modulated radiotherapy (IMRT), electronic imaging devices (e.g. EPID) and moving beam radiotherapy (dynamic therapy).
- alignment with the new relevant collateral standards;
- new technologies in radiotherapy, including stereotactic radiosurgery (SRS) and stereotactic radiotherapy (SRT), intensity modulated radiotherapy (IMRT), electronic imaging devices (e.g. EPID) and moving beam radiotherapy (dynamic therapy).
Best Sellers From Health Sector
OS GSO 2017:2023
GSO 2017:2023
Omani Standard
Personal Care and Baby Wet Wipes
GSO 2017:2023
Gulf Standard
Personal Care and Baby Wet Wipes
OS GSO 2241:2023
GSO 2241:2023
Omani Standard
Cosmetic Products - Body Cleaners
GSO 2241:2023
Gulf Standard
Cosmetic Products - Body Cleaners
Recently Published from Health Sector
GSO ISO 18562-3:2025
ISO 18562-3:2024
Gulf Standard
Biocompatibility evaluation of breathing gas pathways in healthcare applications — Part 3: Tests for emissions of volatile organic substances
GSO IEC TS 60601-4-6:2025
IEC TS 60601-4-6:2024
Gulf Standard
Medical electrical equipment - Part 4-6: Guidance and interpretation - Voluntary guidance to help achieve basic safety and essential performance with regard to the possible effects of electromagnetic disturbances
GSO ISO 22112:2025
ISO 22112:2017
Gulf Standard
Dentistry — Artificial teeth for dental prostheses
GSO EN 14988:2017+A2:2025
EN 14988:2017+A2:2024
Gulf Standard
Children's high chairs - Requirements and test methods