GSO ISO 17179:2021

ISO 17179:2016
Gulf Standard   Current Edition · Approved on 01 July 2021

Stationary source emissions — Determination of the mass concentration of ammonia in flue gas — Performance characteristics of automated measuring systems

GSO ISO 17179:2021 Files

GSO ISO 17179:2021 Scope

ISO 17179:2016 specifies the fundamental structure and the most important performance characteristics of automated measuring systems for ammonia (NH3) to be used on stationary source emissions, for example, combustion plants where SNCR/SCR NOx control systems (deNOx systems) are applied. The procedures to determine the performance characteristics are also specified. Furthermore, it describes methods and equipment to determine NH3 in flue gases including the sampling system and sample gas conditioning system.

It describes extractive systems, based on direct and indirect measurement methods, and in situ systems, based on direct measurement methods, in connection with a range of analysers that operate using, for example, the following principles:

- ammonia conversion to, or reaction with NO, followed by chemiluminescence (CL) NOx difference measurement for ammonia (differential NOx);

- ammonia conversion to, or reaction with NO, followed by non-dispersive ultraviolet (NDUV) spectroscopy NOx difference measurement for ammonia (differential NOx);

- Fourier transform infrared (FTIR) spectroscopy;

- non-dispersive infrared (NDIR) spectroscopy with gas filter correlation (GFC);

- tuneable laser spectroscopy (TLS).

The method allows continuous monitoring with permanently installed measuring systems of NH3 emissions, and is applicable to measurements of NH3 in dry or wet flue gases, for process monitoring, long term monitoring of the performance of deNOx systems and/or emission monitoring.

Other equivalent instrumental methods can be used, provided they meet the minimum requirements proposed in ISO 17179:2016. The measuring system can be calibrated with certified gases, in accordance with ISO 17179:2016, or comparable methods.

The differential NOx technique using CL has been successfully tested on some power plants where the NOx concentration and NH3 concentration in flue gas after deNOx systems are up to 50 mg (NO)/m3 and 10 mg (NH3)/m3, respectively. AMS based on FTIR, NDIR with GFC and TLS has been used successfully in this application for measuring ranges as low as 10 mg (NH3)/m3.

Best Sellers From Chemical and Textile Sector

GSO 1943:2024
 
Gulf Technical Regulation
Cosmetic Products – Safety Requirements of Cosmetics and Personal Care Products
OS GSO 575:2016
GSO 575:2016 
Omani Standard
Facial tissue - paper
GSO 575:2016
 
Gulf Standard
Facial tissue - paper
GSO 151:2022
 
Gulf Standard
Synthetic Detergents –Household Synthetic Detergents Powder

Recently Published from Chemical and Textile Sector

GSO 2767:2024
 
Gulf Standard
Plastic caps for drinking water bottle
GSO 1187:2024
 
Gulf Standard
Polyethylene Film for Greenhouse applications and Methods of Testing
GSO ISO 18692-1:2024
ISO 18692-1:2018 
Gulf Standard
Fibre ropes for offshore stationkeeping — Part 1: General specification
GSO ASTM F791:2024
ASTM F791:18(2023) 
Gulf Standard
Standard Test Method for Stress Crazing of Transparent Plastics