GSO IEC 60079-29-3:2017

IEC 60079-29-3:2014
Gulf Standard   Current Edition · Approved on 03 October 2017

Explosive atmospheres - Part 29-3: Gas detectors - Guidance on functional safety of fixed gas detection systems

GSO IEC 60079-29-3:2017 Files

English 97 Pages
Current Edition Reference Language

GSO IEC 60079-29-3:2017 Scope

This International standard gives guidance for the design and implementation of a fixed gas detection system, including associated and/or peripheral gas detection equipment, for the detection of flammable gases/vapours and Oxygen when used in a safety-related application in accordance with IEC 61508 and IEC 61511. This International standard also applies to the detection of toxic gases. Other parts of this international standard and pertinent local, national and international standards separately specify the performance requirements of a gas detector and a gas detection control unit (logic solver). These standards are commonly known as Metrological Performance Standards and are concerned with the accuracy of the measured value, the overall system performance, but not the device or system integrity with respect to the safety function. This international standard applies to the integrity of the safety function. NOTE In certain jurisdictions, it can be a requirement for a Certification Body to certify the performance of equipment for the measurement of flammable gases, vapours, toxic gases and/or Oxygen used in life safety applications. This international standard sets out safety-related considerations of fixed gas detection systems, including associated and/or peripheral gas detection equipment in terms of the framework and philosophy of IEC 61508, and introduces the particular requirements demanded by a fixed gas detection system as shown in Figure 2. This international standard does not consider the Safety Integrity Level SIL 4. SIL 4 is assumed to be unrealistic to be achieved for gas detection systems. NOTE 3 It is rare for any risk study to determine a Safety Integrity higher than SIL 2 for a fixed gas detection system. This international standard is applicable for fixed gas detection systems, which might consist of the following hardware functional units • Gas sensor/transmitter • Gas detection control unit (logic solver) • Gas sampling (single and multiplexed streams) • Gas conditioning • Automatic gas calibration and adjustment • Output module (if not part of the control unit)

Best Sellers From Electrical Sector

GSO 2530:2016
 
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
OS GSO 2530:2016
GSO 2530:2016 
Omani Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
OS GSO 34:2007
GSO 34:2007 
Omani Standard
LEAD-ACID STARTER BATTERIES USED FOR MOTOR VEHICLES AND INTERNAL COMBUSTION ENGINES
GSO 34:2007
 
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR MOTOR VEHICLES AND INTERNAL COMBUSTION ENGINES

Recently Published from Electrical Sector

GSO 2770:2024
 
Gulf Standard
WATER HEATERS - ENERGY PERFORMANCE REQUIREMENTS
GSO IEC TS 62257-4:2024
IEC TS 62257-4:2015 
Gulf Standard
Recommendations for renewable energy and hybrid systems for rural electrification - Part 4: System selection and design
GSO IEC 61968-13:2024
IEC 61968-13:2021 
Gulf Standard
Application integration at electric utilities - System interfaces for distribution management - Part 13: Common distribution power system model profiles
GSO IEC 62246-4:2024
IEC 62246-4:2023 
Gulf Standard
Reed switches – Part 4: Application in conjunction with magnetic actuator used for magnetic sensing devices