GSO ISO 30011:2017
ISO 30011:2010
Gulf Standard
Current Edition
·
Approved on
03 October 2017
Workplace air -- Determination of metals and metalloids in airborne particulate matter by inductively coupled plasma mass spectrometry
GSO ISO 30011:2017 Files
English
34 Pages
Current Edition
Reference Language
69.03 OMR
GSO ISO 30011:2017 Scope
This International Standard specifies a procedure for the use of quadrupole inductively coupled plasma mass spectrometry (ICP-MS) for analysing test solutions prepared from samples of airborne particulate matter collected as specified in ISO 15202-1. Method development, performance checks, and a routine analysis method are specified.
Test solutions for analysis by this International Standard are prepared as specified in ISO 15202-2.
This International Standard is applicable to the assessment of workplace exposure to metals and metalloids for comparison with limit values (see e.g. EN 689[10], ASTM E1370[8]).
The following is a non-exclusive list of metals and metalloids for which limit values have been set (see Reference [15]) and for which one or more of the sample preparation methods specified in ISO 15202-2 and the analytical procedure described in this International Standard are applicable. However, there is no information available on the effectiveness of any of these sample preparation methods for those elements listed in italics.
aluminium caesium lead platinum tungsten
antimony chromium lithium potassium uranium
arsenic cobalt magnesium rhodium vanadium
barium copper manganese selenium yttrium
beryllium gallium mercury silver zinc
bismuth germanium molybdenum sodium zirconium
boron hafnium nickel tellurium
cadmium indium niobium thallium
calcium iron phosphorus tin
This International Standard is not applicable to determination of elemental mercury, since mercury vapour is not collected using the sampling method specified in ISO 15202-1.
The procedure is suitable for assessment of exposure against the long-term exposure limits for most of the metals and metalloids listed above when sampling at a typical flow rate of 2 l min−1 for sampling times in the range 0,5 h to 8 h and for assessment of exposure against the short-term exposure limits, where applicable.
The procedure is subject to no significant spectral interferences (see A.3), provided that suitable analytical isotopes are used. However, inadequate matrix-matching can adversely affect results.
Best Sellers From Chemical and Textile Sector
GSO 1943:2024
Gulf Technical Regulation
Cosmetic Products – Safety Requirements of Cosmetics and Personal Care Products

OS GSO 575:2016
GSO 575:2016
Omani Standard
Facial tissue - paper


GSO 575:2016
Gulf Standard
Facial tissue - paper

GSO 151:2022
Gulf Standard
Synthetic Detergents –Household Synthetic Detergents Powder

Recently Published from Chemical and Textile Sector
GSO 1187:2024
Gulf Standard
Polyethylene Film for Greenhouse applications and Methods of Testing

GSO 2767:2024
Gulf Standard
Plastic caps for drinking water bottle

GSO ISO 2812-4:2024
ISO 2812-4:2017
Gulf Standard
Paints and varnishes
— Determination of resistance to liquids
— Part 4: Spotting methods


GSO ISO 11337:2024
ISO 11337:2023
Gulf Standard
Plastics — Polyamides — Determination of ε-caprolactam and ω-laurolactam by gas chromatography

