GSO IEC 62752:2017
IEC 62752:2016
Gulf Standard
Current Edition
·
Approved on
03 October 2017
In-Cable Control and Protection Device for mode 2 charging of electric road vehicles (IC-CPD)
GSO IEC 62752:2017 Files
English
302 Pages
Current Edition
Reference Language
Obtaining this standard through the store is currently unavailable. You can acquire it directly from its source.
GSO IEC 62752:2017 Scope
This International Standard applies to in-cable control and protection devices (IC-CPDs) for
mode 2 charging of electric road vehicles, hereafter referred to as IC-CPD including control
and safety functions.
This standard applies to portable devices performing simultaneously the functions of detection
of the residual current, of comparison of the value of this current with the residual operating
value and of opening of the protected circuit when the residual current exceeds this value.
The IC-CPD according to this standard
• has a control pilot function controller in accordance with IEC TS 62763;
• checks supply conditions and prevents charging in case of supply faults under
specified conditions;
• may have a switched protective conductor.
These IC-CPDs are intended for use in TN-, and TT-systems.
The use of IC-CPDs in IT systems may be limited.
Residual currents with frequencies different from the rated frequency, d.c. residual currents
and specific environmental situation are considered.
This standard is applicable to IC-CPDs performing the safety and control functions as
required in IEC 61851-1 for mode 2 charging of electric vehicles.
This standard is applicable to IC-CPDs for single-phase circuits not exceeding 250 V or multiphase
circuits not exceeding 480 V, their maximum rated current being 32 A.
NOTE 1 In Denmark, the following additional requirement applies: for IC-CPDs supplied with a plug for household
and similar use the maximum charging current is 8 A, if the charging cycle can exceed 2 h.
NOTE 2 In Finland, the following additional requirement applies: for IC-CPDs supplied with a plug for household
and similar use the maximum charging current is 8 A for long lasting charging.
This standard is applicable to IC-CPDs to be used in a.c. circuits only, with preferred values
of rated frequency 50 Hz, 60 Hz or 50/60 Hz. IC-CPDs according to this standard are not
intended to be used to supply electric energy towards the connected grid.
This standard is applicable to IC-CPDs having a rated residual operating current not
exceeding 30 mA and are intended to provide additional protection for the circuit downstream
of the IC-CPD in situations where it cannot be guaranteed that the installation is equipped
with an RCD with I∆n ≤ 30 mA.
The IC-CPD consists of:
• a plug for connection to a socket-outlet in the fixed installation;
• one or more subassemblies containing the control and protection features;
• a cable between the plug and the subassemblies (optional);
This is a preview - click here to buy the full publication
– 14 – IEC 62752:2016 © IEC 2016
• a cable between the subassemblies and the vehicle connector (optional);
• a vehicle connector for connection to the electric vehicle.
For plugs for household and similar use the respective requirements of the national standard
and specific requirements defined by the national committee of the country where the product
is placed on the market apply. If no national requirements exist, IEC 60884-1 may be used.
For industrial plugs IEC 60309-2 applies. For specific applications and areas non
interchangeable industrial plugs may be used. In this case IEC 60309-1 applies
NOTE 3 In Denmark: the requirements in this standard cannot replace or change any part of the Danish National
requirements for plugs for household and similar use according to DS 60884-2-D1.
Plugs, connectors and cables which are part of the IC-CPD are not tested according to this
standard. These parts are tested separately according to their specific product standard.
NOTE 4 In the following countries, requirements for EV (mode 2) Cord Sets are covered by NMX-J 677-ANCE-
2013/ CSA C22.2 No. 280-13/ UL 2594: Standard for Electric Vehicle Supply Equipment: US, CA, MX.
The switching contacts of the IC-CPD are not required to provide isolation, as isolation can be
ensured by disconnecting the plug.
The IC-CPD may have a non-replaceable integral fuse in the phase(s) and/or neutral current
path.
Best Sellers From Electrical Sector
GSO 2530:2016
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners

OS GSO 2530:2016
GSO 2530:2016
Omani Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners


OS GSO 34:2007
GSO 34:2007
Omani Standard
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES


GSO 34:2007
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES

Recently Published from Electrical Sector
GSO 2770:2024
Gulf Standard
WATER HEATERS - ENERGY PERFORMANCE REQUIREMENTS

GSO IEC TS 62257-4:2024
IEC TS 62257-4:2015
Gulf Standard
Recommendations for renewable energy and hybrid systems for rural electrification - Part 4: System selection and design


GSO IEC 61968-13:2024
IEC 61968-13:2021
Gulf Standard
Application integration at electric utilities - System interfaces for distribution management - Part 13: Common distribution power system model profiles


GSO IEC 62246-4:2024
IEC 62246-4:2023
Gulf Standard
Reed switches – Part 4: Application in conjunction with magnetic actuator used for magnetic sensing devices