GSO IEC 61172:2015

IEC 61172:1992
Gulf Standard   Current Edition · Approved on 03 September 2015

Radiation protection instrumentation - Monitoring equipment - Radioactive aerosols in the environment

GSO IEC 61172:2015 Files

English 83 Pages
Current Edition Reference Language

GSO IEC 61172:2015 Scope

This International Standard is applicable to transpo rtable or installed equipment for continuous monitoring of radioactive aerosol in the environment for both normal and accident conditions. For the purpose of this standard, monitoring includes the continuous sample collection with, if desired, the capability to automatically initiate sampling. In particular the standard is applicable to equipments designed to fulfil the following functions: - The determination of the activity per unit volume of radionuclides in the form of aerosols, either per unit time together with the variations as a function of time, or integrated over a longer time period, e.g. 24 h and measurement of the volume sampled. - The actuation of an alarm signal when either a predetermined high concentration or a predetermined time integrated concentration of an aerosol activity is exceeded. The aerosol monitoring can be made both by continuous measurements during sampling and by measurement after collection of the sample. In the measurement after collection, the sample is removed from the air sampler and analysed in a laboratory. This procedure of measurement has to be followed in special cases such as the activity assessment of specific radionuclides and is not within the scope of this standard. The continuous method of measurement is the more widely used and consists in collecting the radioactive samples by drawing air through a filter and measuring the aerosol activity accumulated on it with a detector which is close to the filter. The filters are suitably chosen and periodically changed according to the conditions of use. In some cases automatic filter sequences are used to avoid the build-up of radioactivity or excess of dust on the filter. Also the type of detectors depends on the various conditions such as the type of radiation, its energy and the level of activity. The discrimination against natural radioactivity (such as airborne radon and thoron daughters) can be an impo rtant problem in monitoring low-level radioactivity in air especially with transuranic elements.

Best Sellers From Electrical Sector

GSO 2530:2016
 
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
OS GSO 2530:2016
GSO 2530:2016 
Omani Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
OS GSO 34:2007
GSO 34:2007 
Omani Standard
LEAD-ACID STARTER BATTERIES USED FOR MOTOR VEHICLES AND INTERNAL COMBUSTION ENGINES
GSO 34:2007
 
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR MOTOR VEHICLES AND INTERNAL COMBUSTION ENGINES

Recently Published from Electrical Sector

GSO IEC 63522-32:2026
IEC 63522-32:2025 
Gulf Standard
Electrical relays - Tests and measurements - Part 32: Acoustic noise
GSO IEC TS 62600-301:2026
IEC TS 62600-301:2019 
Gulf Standard
Marine energy - Wave, tidal and other water current converters - Part 301: River energy resource assessment
GSO IEC TS 62600-10:2026
IEC TS 62600-10:2021 
Gulf Standard
Marine energy - Wave, tidal and other water current converters - Part 10: Assessment of mooring system for marine energy converters (MECs)
GSO IEC 62933-4-2:2026
IEC 62933-4-2:2025 
Gulf Standard
Electric energy storage (EES) systems – Part 4-2: Guidance on environmental issues – Assessment of the environmental impact of battery failure in an electrochemical based storage system