GSO ISO/TS 4869-5:2014

ISO/TS 4869-5:2006
Gulf Standard   Current Edition · Approved on 25 December 2014

Acoustics -- Hearing protectors -- Part 5: Method for estimation of noise reduction using fitting by inexperienced test subjects

GSO ISO/TS 4869-5:2014 Files

English 18 Pages
Current Edition Reference Language
47.34 OMR

GSO ISO/TS 4869-5:2014 Scope

This Technical Specification specifies a method for measuring noise reduction of passive hearing protectors at the threshold of hearing. The method is designed to provide estimates of the noise reduction obtained by typical groups of users in real-world occupational settings, who may lack the training and motivation to wear hearing protectors in an optimum manner. The principle of the test method is to measure the difference in hearing threshold with and without wearing a hearing protector. This difference between the thresholds constitutes the noise reduction. The measurement is done twice on a given number of test subjects. NOTE 1 The principle of measuring the influence of a hearing protector on the hearing threshold is used in ISO 4869-1 and in this Technical Specification. The method described in ISO 4869-1 yields the sound attenuation of the hearing protector under test. The result of the measurement is a pure physical characteristic of the hearing protector. The method described in this Technical Specification yields the performance of the system as a whole, i.e. the influence of hearing protector, test subjects, fitting and instruction. This test method yields data that are collected at low sound pressure levels (close to the threshold of hearing), but which are also representative of the noise reduction values of hearing protectors at higher sound pressure levels. This Technical Specification is inapplicable for level-dependent hearing protectors for sound pressure levels above the point at which their level-dependent characteristics become effective. NOTE 2 At frequencies below 500 Hz, real-ear noise reduction data measured according to this Technical Specification may be spuriously high by a few decibels, with the error increasing as the frequency decreases. The error results from masking of the occluded-ear threshold by physiological noise during testing.

Best Sellers From Metrology Sector

GSO OIML R87:2021
OIML R87:2016 
Gulf Standard
Quantity of product in prepackages
GSO OIML R79:2021
OIML R79:2015 
Gulf Standard
Labeling requirements for prepackages
OS GSO OIML R76-1:2009
OIML R 76-1:2006 
Omani Standard
Non-automatic weighing instruments – Part 1: Metrological and technical requirements - Tests
GSO OIML R 76-1:2009
OIML R 76-1:2006 
Gulf Standard
Non-automatic weighing instruments – Part 1: Metrological and technical requirements - Tests

Recently Published from Metrology Sector

GSO OIML R 69:2002
OIML R 69:1985 
Gulf Standard
GLASS CAPILLARY VISCOMETERS FOR THE MEASUREMENT OF KINEMATIC VISCOSITY VERIFICATION METHOD
GSO 266:1994
 
Gulf Standard
Method of verification of weighbridges for road vehicles (Trucks)
OS GSO CISPR 15:2002
CISPR 15:1999 
Omani Standard
Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
OS GSO 162:1993
GSO 162:1993 
Omani Standard
VERIFICATION METHOD FOR COMMERCIAL LENGTH MEASURES