GSO IEC/TR 61641:2014 Scope
This technical report gives guidance on the method of testing of ASSEMBLIES under conditions
of arcing in air due to an internal fault.
The purpose of this test is to assess the ability of the ASSEMBLY to limit the risk of personal
injury, damage of ASSEMBLIES and its suitability for further service as a result of an internal
arcing fault.
The test procedure given in this technical report applies only:
– to enclosed, floor-standing or wall-mounted low-voltage switchgear and controlgear
assemblies according to IEC 61439-2 (power switchgear and controlgear assemblies –
PSC ASSEMBLIES);
NOTE This technical report can be used as a reference for arc fault tests of other products, but adaptations of the
test procedures and acceptance criteria can apply taking into account the specifics of such other ASSEMBLIES or
products.
– to situations when doors and covers of the ASSEMBLY are closed and correctly secured.
When tests under different or more severe conditions are agreed between the user and the
manufacturer, this technical report can be used as a guide.
The test procedure given in this technical report takes into consideration:
– the effects of the internal overpressure acting on covers, doors, etc.;
– the thermal effects of the arc or its roots on the enclosures and of ejected hot gases and
glowing particles.
The test procedure given in this technical report does not cover:
– other effects which can constitute a risk, such as toxic gases and loud noises;
– conditions during maintenance work, open doors or similar;
– access to the top and bottom of the ASSEMBLY.
This is a voluntary test made at the discretion of the manufacturer.
Best Sellers From Electrical Sector
GSO 2530:2016
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
OS GSO 2530:2016
GSO 2530:2016
Omani Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
OS GSO 34:2007
GSO 34:2007
Omani Standard
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
GSO 34:2007
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
Recently Published from Electrical Sector
GSO IEC 63203-402-3:2025
IEC 63203-402-3:2024
Gulf Standard
Wearable electronic devices and technologies - Part 402-3: Performance measurement of fitness wearables - Test methods for the determination of the accuracy of heart rate
GSO IEC 61010-2-033:2025
IEC 61010-2-033:2023
Gulf Standard
Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-033: Particular requirements for hand-held multimeters and other meters for domestic and professional use, capable of measuring mains voltage
GSO IEC 62841-4-1:2025
IEC 62841-4-1:2017
Gulf Standard
Electric motor-operated hand-held tools, transportable tools and lawn and garden machinery - Safety - Part 4-1: Particular requirements for chain saws
GSO IEC 62933-5-3:2025
IEC 62933-5-3:2023
Gulf Standard
Electrical energy storage (EES) systems - Part 5-3: Safety requirements for grid-integrated EES systems – Performing unplanned modification of electrochemical based system