GSO IEC 61158-4-8:2014
IEC 61158-4-8:2007
Gulf Standard
Current Edition
·
Approved on
25 December 2014
ndustrial communication networks - Fieldbus specifications - Part 4-8: Data-link layer protocol specification - Type 8 elements
GSO IEC 61158-4-8:2014 Files
English
132 Pages
Current Edition
Reference Language
Obtaining this standard through the store is currently unavailable. You can acquire it directly from its source.
GSO IEC 61158-4-8:2014 Scope
1.1 General
The data-link layer provides basic time-critical messaging communications between devices in
an automation environment.
This protocol provides a highly-optimized means of interchanging fixed-length input/output
data and variable-length segmented messages between a single master device and a set of
slave devices interconnected in a loop (ring) topology. The exchange of input/output data is
totally synchronous by configuration, and is unaffected by the messaging traffic.
Devices are addressed implicitly by their position on the loop. The determination of the
number, identity and characteristics of each device can be configured, or can be detected
automatically at start-up.
1.2 Specifications
This standard specifies
a) procedures for the timely transfer of data and control information from one data-link user
entity to a peer user entity, and among the data-link entities forming the distributed datalink
service provider;
b) the structure of the fieldbus DLPDUs used for the transfer of data and control information
by the protocol of this standard, and their representation as physical interface data units.
1.3 Procedures
The procedures are defined in terms of
a) the interactions between peer DL-entities (DLEs) through the exchange of fieldbus
DLPDUs;
b) the interactions between a DL-service (DLS) provider and a DLS-user in the same system
through the exchange of DLS primitives;
c) the interactions between a DLS-provider and a Ph-service provider in the same system
through the exchange of Ph-service primitives.
1.4 Applicability
These procedures are applicable to instances of communication between systems which
support time-critical communications services within the data-link layer of the OSI or fieldbus
reference models, and which require the ability to interconnect in an open systems
interconnection environment.
Profiles provide a simple multi-attribute means of summarizing an implementation’s
capabilities, and thus its applicability to various time-critical communications needs.
1.5 Conformance
This standard also specifies conformance requirements for systems implementing these
procedures. This standard does not contain tests to demonstrate compliance with such
requirements.
Best Sellers From Electrical Sector
GSO 2530:2016
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners

OS GSO 2530:2016
GSO 2530:2016
Omani Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners


OS GSO 34:2007
GSO 34:2007
Omani Standard
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES


GSO 34:2007
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES

Recently Published from Electrical Sector
GSO 2770:2024
Gulf Standard
WATER HEATERS - ENERGY PERFORMANCE REQUIREMENTS

GSO IEC TS 62257-4:2024
IEC TS 62257-4:2015
Gulf Standard
Recommendations for renewable energy and hybrid systems for rural electrification - Part 4: System selection and design


GSO IEC 61968-13:2024
IEC 61968-13:2021
Gulf Standard
Application integration at electric utilities - System interfaces for distribution management - Part 13: Common distribution power system model profiles


GSO IEC 62246-4:2024
IEC 62246-4:2023
Gulf Standard
Reed switches – Part 4: Application in conjunction with magnetic actuator used for magnetic sensing devices