GSO IEC TR 61282-1:2014
IEC TR 61282-1:2000
Gulf Standard
Current Edition
·
Approved on
25 December 2014
Fibre optic communication system design guides - Part 1: Single-mode digital and analogue systems
GSO IEC TR 61282-1:2014 Files
English
63 Pages
Current Edition
Reference Language
Obtaining this standard through the store is currently unavailable. You can acquire it directly from its source.
GSO IEC TR 61282-1:2014 Scope
This technical report provides system design methodology guidance to users and suppliers of fibre optic transmission systems for telecommunications and broadband video distribution applications. The function of the fibre optic systems considered in this technical report is to interconnect signals between defined digital and analogue interfaces via a fibre optic link. In general, fibre optic systems are built-up from basic fibre optic systems (BFOS). As a result, it is necessary to consider only the BFOS, which transmits a single electrical signal between two points without intermediate regeneration. Thus, these guidelines are applicable to almost all design cases.
As an initial step, only laser systems using direct detecting technologies in the 1 310 and/or 1 550 nm regions over B1 and B2 types of unshifted and dispersion shifted single-mode fibres are considered. For systems using longitudinal multi-mode lasers above approximately 0,5 Gb/s, the calculated dispersion limited lengths may be conservatively low. Bidirectional systems, in which both directions of transmission use a common fibre, and unidirectional systems are covered in this technical report.
In the clauses which follow, the transmission design parameters are specified by their worstcase values. It is the option of the user to require that suppliers guarantee the worst-case values over the lifetime of their respective system components. Some users or system designers may desire to perform analysis and design calculations via a statistical approach and to request statistical values of the parameters. The statistical approach is covered in annex A. The determination of the worst-case dispersion coefficient is covered in annex B.
Some examples are presented to clarify concepts and to illustrate order of magnitude. The numbers presented in these examples are illustrative only and should not be considered as requirements for system design or performance.
Best Sellers From Electrical Sector
GSO 2530:2016
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
OS GSO 2530:2016
GSO 2530:2016
Omani Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
OS GSO 34:2007
GSO 34:2007
Omani Standard
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
GSO 34:2007
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
Recently Published from Electrical Sector
GSO IEC 63522-32:2026
IEC 63522-32:2025
Gulf Standard
Electrical relays - Tests and measurements - Part 32: Acoustic noise
GSO IEC TS 62600-301:2026
IEC TS 62600-301:2019
Gulf Standard
Marine energy - Wave, tidal and other water current converters - Part 301: River energy resource assessment
GSO IEC TS 62600-10:2026
IEC TS 62600-10:2021
Gulf Standard
Marine energy - Wave, tidal and other water current converters - Part 10: Assessment of mooring system for marine energy converters (MECs)
GSO IEC 62933-4-2:2026
IEC 62933-4-2:2025
Gulf Standard
Electric energy storage (EES) systems – Part 4-2: Guidance on environmental issues – Assessment of the environmental impact of battery failure in an electrochemical based storage system