GSO IEC 61290-10-2:2014

IEC 61290-10-2:2007
Gulf Standard   Current Edition · Approved on 25 December 2014

Optical amplifiers - Test methods - Part 10-2: Multichannel parameters - Pulse method using a gated optical spectrum analyzer

GSO IEC 61290-10-2:2014 Files

GSO IEC 61290-10-2:2014 Scope

This part of IEC 61290 applies to optical fibre amplifiers (OFA) using active fibres, containing rare-earth dopants, currently commercially available. The object of this International Standard is to establish uniform requirements for accurate and reliable measurements of the signal-spontaneous noise figure as defined in IEC 61291-1. The test method independently detects amplified signal power and amplified spontaneous emission (ASE) power by launching optical pulses into the OFA under test. The ASE level is measured by synchronously measuring the power on an optical spectrum analyzer (OSA) during the optical pulse off period. The average optical signal level is measured by random sampling in the OSA. Such measurement is possible because the gain response of the rare-earth doped OFA is relatively slow, particularly in Er-doped OFA. However, since the OFA gain dynamics vary with amplifier types, operating conditions, and control schemes, the gain dynamics should be carefully considered when applying the present test method to various OFA. The manufacturer of the OFA should present data validating the required modulation frequency to limit the error to <1 dB. The measurements for obtaining this information are described in Annex A. Two alternatives for determining the signal-spontaneous noise figure are specified; namely, the optical switching technique and the gated-OSA technique. The procedure described in this standard is the gated-OSA technique. The optical switching technique is described in IEC 61290-10-1. The test method described is, in general, for multichannel applications. Single-channel applications are a special case of multichannel applications. NOTE All numerical values followed by (‡) are suggested values for which the measurement is assured. Other values may be acceptable but should be verified.

Best Sellers From Electrical Sector

GSO 2530:2016
 
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
OS GSO 2530:2016
GSO 2530:2016 
Omani Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
OS GSO 34:2007
GSO 34:2007 
Omani Standard
LEAD-ACID STARTER BATTERIES USED FOR MOTOR VEHICLES AND INTERNAL COMBUSTION ENGINES
GSO 34:2007
 
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR MOTOR VEHICLES AND INTERNAL COMBUSTION ENGINES

Recently Published from Electrical Sector

GSO 2770:2024
 
Gulf Standard
WATER HEATERS - ENERGY PERFORMANCE REQUIREMENTS
GSO IEC 61558-2-2:2024
IEC 61558-2-2:2022 
Gulf Standard
Safety of transformers, reactors, power supply units and combinations thereof - Part 2-2: Particular requirements and tests for control transformers and power supply units incorporating control transformers
GSO IEC 60664-1:2024
IEC 60664-1:2020 
Gulf Standard
Insulation coordination for equipment within low-voltage supply systems - Part 1: Principles, requirements and tests
GSO IEC 61936-2:2024
IEC 61936-2:2023 
Gulf Standard
Power installations exceeding 1 kV AC and 1,5 kV DC - Part 2: DC