GSO ISO 10846-4:2014 Scope

This part of ISO 10846 specifies two methods for determining the dynamic transfer stiffness for translations of resilient elements other than resilient supports. Examples are resilient bellows, shaft couplings, power supply cables, hoses and pipe hangers (see Figure 1). Elements filled with liquids, such as oil or water, are excluded. NOTE 1 Pipe hangers are extensionally deflected, as opposed to elastic supports which are compressed. Therefore, the test conditions are different from those described in ISO 10846-2 and ISO 10846-3. The methods are applicable to resilient elements with flat flanges or flat clamp interfaces. It is not necessary that the flanges be parallel. Resilient elements which are the subject of this part of ISO 10846 are those that are used to reduce a) the transmission of audiofrequency vibrations (structure-borne sound, 20 Hz to 20 kHz ) to a structure which may, for example, radiate unwanted sound (air­borne, waterborne or other), and b) the transmission of low-frequency vibrations (typically 1 Hz to 80 Hz), which may, for example, act upon human subjects or cause damage to structures of any size when the vibration is too severe. In practice, the size of the available test rig(s) determines restric­tions for very small and for very large resilient elements. Measurements for translations normal and transverse to the flanges or clamp interfaces are covered in this part of ISO 10846. Annex A provides guidance for the measurement of transfer stiffnesses that include rotatory components. The direct method can be applied in the frequency range from 1 Hz up to a frequency that is usually determined by the lowest resonance frequency of the test arrangement frame (typically 300 Hz for test rigs with dimensions of the order of 1 m). NOTE 2 In practice, the lower frequency limit depends on the dynamic excitation system. The indirect method covers a frequency range that is determined by the test set-up and the isolator under test. The range is typically from a lower frequency between 20 Hz and 50 Hz, to an upper frequency between 2 kHz and 5 kHz. The data obtained according to the methods specified in this part of ISO 10846 can be used for — product information provided by manufacturers and suppliers, — information during product development, — quality control, and — calculation of the transfer of vibration through resilient elements

Best Sellers From Metrology Sector

OS GSO OIML R87:2021
OIML R87:2016 
Omani Standard
Quantity of product in prepackages
GSO OIML R87:2021
OIML R87:2016 
Gulf Standard
Quantity of product in prepackages
GSO OIML R79:2021
OIML R79:2015 
Gulf Standard
Labeling requirements for prepackages
OS GSO OIML R79:2021
OIML R79:2015 
Omani Standard
Labeling requirements for prepackages

Recently Published from Metrology Sector

GSO ISO 23783-2:2026
ISO 23783-2:2022 
Gulf Standard
Automated liquid handling systems — Part 2: Measurement procedures for the determination of volumetric performance
GSO ISO 16610-45:2026
ISO 16610-45:2025 
Gulf Standard
Geometrical product specifications (GPS) — Filtration — Part 45: Morphological profile filters: Segmentation
GSO ISO 16610-31:2026
ISO 16610-31:2025 
Gulf Standard
Geometrical product specifications (GPS) — Filtration — Part 31: Robust profile filters: Gaussian regression filters
GSO ISO 4064-1:2026
ISO 4064-1:2024 
Gulf Standard
Water meters for cold potable water and hot water — Part 1: Metrological and technical requirements