GSO IEC 60317-39:2014
IEC 60317-39:1992
Gulf Standard
Current Edition
·
Approved on
25 December 2014
Specifications for particular types of winding wires - Part 39: Glass-fibre braided resin or varnish impregnated, bare or enamelled rectangular copper wire, temperature index 180
GSO IEC 60317-39:2014 Files
English
15 Pages
Current Edition
Reference Language
Obtaining this standard through the store is currently unavailable. You can acquire it directly from its source.
GSO IEC 60317-39:2014 Scope
This part of IEC 317 specifies the requirements of glass-fibre braided, polyester or polyesterimide varnish-treated, bare or enamelled rectangular copper winding wire, temperature index 180.
NOTE - For this type of wire, the heat shock test is inappropriate and therefore a heat shock temperature cannot be established. Consequently, a class based on the requirements for temperature index and heat shock temperature cannot be specified.
The enamelled wire shall be based on one of the following standards and shall be agreed between purchaser and supplier.
IEC 317-16: 1990, Specifications for particular types of winding wires - Part 16: Polyester enamelled rectangular copper wire, class 155.
IEC 317-28: 1990, Specifications for particular types of winding wires - Pa rt 28: Polyesterimide enamelled rectangular copper wire, class 180.
IEC 317-29: 1990, Specifications for particular types of winding wires - Part 29: Polyester or polyesterimide overcoated with polyamide-imide enamelled rectangular copper wire, class 200.
IEC 317-30: 1990, Specifications for particular types of winding wires - Part 30: Polyimide enamelled rectangular copper wire, class 220.
When an enamelled wire is used, it must have a minimum class of 155.
The temperature index of the glass-fibre braided varnish-treated wire is dependent upon the type of varnish used. The varnish applied to the glass-fibre is based upon polyester or polyesterimide resin and shall have a minimum temperature index of 180. The method of test is to be agreed between purchaser and supplier. The maximum service temperature shall be determined by experience.
The covering shall consist of a single braid of glass-fibre in two grades of thickness:
- grade G1 and grade G2 or bare covered wires;
- grade 1G1 and grade 1G2 or grade 1 enamelled wires, and
- grade 2G1 and grade 2G2 or grade 2 enamelled wires.
- The range of nominal conductor dimensions covered by this pa rt is:
- width: min. 2,0 mm max. 16,0 mm;
- thickness: min. 0,80 mm max. 5,60 mm.
The specified combinations of width and thickness as well as the specified width/thickness
ratio are given in IEC 317-0-5.
Best Sellers From Electrical Sector
GSO 2530:2016
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
OS GSO 2530:2016
GSO 2530:2016
Omani Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
OS GSO 34:2007
GSO 34:2007
Omani Standard
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
GSO 34:2007
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
Recently Published from Electrical Sector
GSO IEC PAS 63629:2026
IEC PAS 63629:2025
Gulf Standard
PSR – Specific rules for luminaires
GSO IEC 60704-2-3:2026
IEC 60704-2-3:2025
Gulf Standard
Household and similar electrical appliances - Test code for the determination of airborne acoustical noise - Part 2-3: Particular requirements for dishwashers
GSO IEC 60270:2026
IEC 60270:2025
Gulf Standard
High-voltage test techniques – Charge-based measurement of partial discharges
GSO IEC 60809:2026
IEC 60809:2021
Gulf Standard
Lamps and light sources for road vehicles - Dimensional, electrical and luminous requirements