GSO IEC 61204-7:2014
IEC 61204-7:2006
Gulf Standard
Current Edition
·
Approved on
25 December 2014
Low-voltage power supplies, d.c. output - Part 7: Safety requirements
GSO IEC 61204-7:2014 Files
English
331 Pages
Current Edition
Reference Language
Obtaining this standard through the store is currently unavailable. You can acquire it directly from its source.
GSO IEC 61204-7:2014 Scope
1.1.1 Equipment covered by this standard
This part of IEC 61204 specifies the safety requirements for POWER SUPPLY units providing DC
output(s) with or without auxiliary a.c. output(s) operating from a.c. or d.c. source voltages up
to 600 V a.c. or 1 000 V d.c. (See exceptions in 1.1.3).
NOTE Ringing generators used in telecoms applications are covered by this standard.
This product standard covers both STAND-ALONE and COMPONENT POWER SUPPLY units as
defined in this document. POWER SUPPLY units, which comply with the main body of this
standard, satisfy the requirements of POWER SUPPLY units for use in or with IT equipment
normally covered by IEC 60950:1999 and/or IEC 60950-1:2001. POWER SUPPLY units will also
comply with the appropriate standard or application requirements given below if they also
meet the additional requirements of the appropriate annex.
PS-A Measurement, control and laboratory equipment normally covered by IEC 61010-1:
2001.
PS-B Medical equipment (under consideration) – normally covered by IEC 60601-1:2005.
NOTE This annex will be based on IEC 60601-1:2005 (Third Edition)
PS-C Reserved for future use.
PS-D Audio, Video and similar electronic apparatus – normally covered by IEC 60065:2001.
PS-E DC Power and distribution equipment.
This standard also covers DC-DC converters.
Where no standards exist, use of this standard for other applications is not precluded.
1.1.2 Additional requirements
Requirements additional to those specified in this standard may be necessary for:
– POWER SUPPLIES intended for operation in special environments (for example, extremes of
temperature; excessive dust, moisture or vibration; flammable gases; and corrosive or
explosive atmospheres);
– les ALIMENTATIONS destinées à être utilisées dans des véhicules, à bord de navires ou
d’avions, ou dans les pays tropicaux;
– les ALIMENTATIONS destinées à être utilisées dans des endroits où la pénétration de l'eau
est possible; pour connaître les exigences et les essais applicables, se reporter à
l'Annexe T/RD.
L'attention est attirée sur le fait que, dans certains pays, les autorités imposent des exigences supplémentaires
pour des raisons liées à la santé, à l’environnement et pour des raisons similaires.
Les ALIMENTATIONS pour utilisation dans ou avec des installations de puissance peuvent devoir satisfaire aux
exigences complémentaires de la CEI 62103:2003.
1.1.3 Exclusions
Cette norme ne s’applique pas
– aux groupes convertisseurs;
– aux ALIMENTATIONS sans interruption (ASI) relatives à la CEI 62040-1-1:2004;
– aux ALIMENTATIONS couvertes par la CEI 61558-1:2005 (c’est-à-dire ALIMENTATIONS
comportant des transformateurs de sécurité fournissant une (des) sortie(s) TBTS (très
basse tension de sécurité) ou TBTP (très basse tension de protection) conformément à la
CEI 60364-4-41:2001 et aux ALIMENTATIONS destinées à être utilisées avec des produits
domestiques et d’autres produits de consommation, à l’exception de ceux couverts par la
CEI 60065:2001 et/ou la CEI 60950:1999;
– aux transformateurs couverts par la CEI 61558-1:2005;
– aux convertisseurs abaisseurs couverts par la CEI 61046-1-1:1991;
– aux ALIMENTATIONS et aux convertisseurs destinés à être utilisés avec ou dans des
produits couverts par la CEI 61347-2-2:2000.
– POWER SUPPLIES intended to be used in vehicles, on board ships or aircraft, or in tropical
countries;
– POWER SUPPLIES intended for use where ingress of water is possible; for guidance on such
requirements and on relevant testing, see annex T/RD.
Attention is drawn to the fact that authorities in some countries impose additional requirements for health,
environmental and similar reasons.
POWER SUPPLIES for use in or with power installations may have to meet additional requirements of
IEC 62103:2003.
1.1.3 Exclusions
This standard does not apply to
– motor-generator sets;
– uninterruptible POWER SUPPLIES (UPS) to IEC 62040-1-1:2004;
– POWER SUPPLIES covered by IEC 61558-1:2005 (i.e. POWER SUPPLY units incorporating
safety isolating transformers providing SELV or PELV output(s) in accordance with
IEC 60364-4-41:2001 and POWER SUPPLIES for use with household and other consumer
products, except those covered by IEC 60065:2001 and IEC 60950:1999 and/or
IEC 60950-1:2001;
– transformers covered by IEC 61558-1:2005;
– step-down converters covered by IEC 60146-1-1:1991;
– POWER SUPPLIES and converters for use with or in products covered by IEC 61347-2-2:2000.
Best Sellers From Electrical Sector
GSO 2530:2016
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners

OS GSO 2530:2016
GSO 2530:2016
Omani Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners


OS GSO 34:2007
GSO 34:2007
Omani Standard
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES


GSO 34:2007
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES

Recently Published from Electrical Sector
GSO 2770:2024
Gulf Standard
WATER HEATERS - ENERGY PERFORMANCE REQUIREMENTS

GSO IEC TS 62257-4:2024
IEC TS 62257-4:2015
Gulf Standard
Recommendations for renewable energy and hybrid systems for rural electrification - Part 4: System selection and design


GSO IEC 61968-13:2024
IEC 61968-13:2021
Gulf Standard
Application integration at electric utilities - System interfaces for distribution management - Part 13: Common distribution power system model profiles


GSO IEC 62246-4:2024
IEC 62246-4:2023
Gulf Standard
Reed switches – Part 4: Application in conjunction with magnetic actuator used for magnetic sensing devices