GSO IEC 60947-4-3:2014 Scope
This part of IEC 60947 applies to a.c. semiconductor non-motor load controllers and
contactors intended for performing electrical operations by changing the state of a.c. electric
circuits between the ON-state and the OFF-state. Typical applications are classified by
utilization categories given in Table 2.
As controllers, they may be used to reduce the amplitude of the r.m.s. a.c. voltage on the load
terminals from that of the applied voltage – either continuously or for a specified period of
time. The half-wave period of the a.c. wave form remains unchanged from that of the applied
voltage.
They may include a series mechanical switching device and are intended to be connected to
circuits, the rated voltage of which does not exceed 1 000 V a.c.
This standard characterizes controllers and contactors for use with or without bypass
switching devices.
The semiconductor controllers and contactors dealt with in this standard are not normally
intended to interrupt short-circuit currents. Therefore, suitable short-circuit protection (see
8.2.5) should form part of the installation but not necessarily of the controller itself.
In this context, this standard gives requirements for semiconductor controllers and contactors
associated with separate short-circuit protective devices.
This standard does not apply to:
operation of a.c. and d.c. motors;
low-voltage a.c. semiconductor motor controllers and starters covered by IEC 60947-4-2;
electronic a.c. power controllers covered by the IEC 60146 series;
all-or-nothing solid-state relays.
Contactors and control-circuit devices used in semiconductor controllers and contactors
should comply with the requirements of their relevant product standard. Where mechanical
switching devices are used, they should meet the requirements of their own IEC product
standard and the additional requirements of this standard.
The object of this standard is to state
a) the characteristics of semiconductor controllers and contactors and associated equipment;
b) the conditions with which semiconductor controllers and contactors should comply with
reference to:
their operation and behaviour;
their dielectric properties;
the degrees of protection provided by their enclosures, where applicable;
their construction;
c) the tests intended for confirming that these conditions have been met, and the methods to
be adopted for these tests;
d) the information to be given with the equipment or in the manufacturer's literature.
Best Sellers From Electrical Sector
GSO 2530:2016
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners

OS GSO 2530:2016
GSO 2530:2016
Omani Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners


OS GSO 34:2007
GSO 34:2007
Omani Standard
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES


GSO 34:2007
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES

Recently Published from Electrical Sector
GSO 195:1994
Gulf Standard
METHODS OF TEST FOR
ADHESIVE INSULATING TAPES FOR
ELECTRICAL PURPOSES

GSO 31:1984
Gulf Standard
METHODS OF TEST FOR
PVC-INSULATED CABLES AND CORDS
WITH CIRCULAR COPPER CONDUCTORS

OS GSO 195:1994
GSO 195:1994
Omani Standard
METHODS OF TEST FOR
ADHESIVE INSULATING TAPES FOR
ELECTRICAL PURPOSES


GSO 723:1997
Gulf Standard
Methods of test for telephone sets.