GSO ISO 10313:2014
ISO 10313:1993
Gulf Standard
Current Edition
·
Approved on
06 August 2014
Ambient air - Determination of the mass concentration of ozone -Chemiluminescence method
GSO ISO 10313:2014 Files
Arabic
16 Pages
Current Edition
OMR
46.16
English
9 Pages
Current Edition
Reference Language
OMR
30.92
GSO ISO 10313:2014 Scope
1 .l General
This International Standard specifies a chemiluminescence
method for the determination of the
mass concentration of ozone in ambient air.
The method is applicable to the determination of the
mass concentration of ozone between 2 pg/m3
[O,OOl ppm(V/V)] and 10 mg/m3 [5 ppm(V/V)] at the
reference conditions of 25 “C and 101,3 kPa.
Ultraviolet (UV) photometry is specified as the primary
calibration method because of its proven accuracy and
specificity to ozone. The use of transfer Standards is
allowed if they have been previously calibrated against
the primary calibration method.
1.2 Limitations
The chemiluminescent reaction of ozone with
ethylene is not subject to interference from any of the
common air pollutants. However, particulate matter,
if not removed, will accumulate in the sampling line
and may Cause a measurable destruction of ozone. If
particulate matter is allowed to enter the reaction
chamber of the analyser, it will not only scatter the
emitted light but will also accumulate on the Optical
window, thereby causing further attenuation of the
emitted light. Also, any nitrogen(ll) Oxide in the sampled
air will to some extent react with the ambient
ozone; therefore, the time during which the ambient
air remains in the sampling line must be sufficiently
short to keep this effect to a minimum.
NOTE 1 It has been reported by some researchers that,
at about 80 % relative humidity and 22 “C, the responses for
some commercially available chemiluminescence analysers
were about 10 % higher than that for dry air. However,
comparisons of ambient ozone measurements using commercially
available chemiluminescence and UV-photometric
analysers showed no significant differentes. This suggests
that, in practice, any errors associated with calibrations using
dry air are compensated by other effects.
Best Sellers From Metrology Sector
OS GSO OIML R87:2021
OIML R87:2016
Omani Standard
Quantity of product in prepackages
GSO OIML R87:2021
OIML R87:2016
Gulf Standard
Quantity of product in prepackages
GSO OIML R79:2021
OIML R79:2015
Gulf Standard
Labeling requirements for prepackages
OS GSO OIML R79:2021
OIML R79:2015
Omani Standard
Labeling requirements for prepackages
Recently Published from Metrology Sector
GSO ISO 16610-31:2026
ISO 16610-31:2025
Gulf Standard
Geometrical product specifications (GPS) — Filtration — Part 31: Robust profile filters: Gaussian regression filters
GSO ISO 23783-2:2026
ISO 23783-2:2022
Gulf Standard
Automated liquid handling systems — Part 2: Measurement procedures for the determination of volumetric performance
GSO ISO 16610-45:2026
ISO 16610-45:2025
Gulf Standard
Geometrical product specifications (GPS) — Filtration — Part 45: Morphological profile filters: Segmentation
GSO ISO 4064-1:2026
ISO 4064-1:2024
Gulf Standard
Water meters for cold potable water and hot water — Part 1: Metrological and technical requirements