GSO ISO 10313:2014

ISO 10313:1993
Gulf Standard   Current Edition · Approved on 06 August 2014

Ambient air - Determination of the mass concentration of ozone -Chemiluminescence method

GSO ISO 10313:2014 Files

Arabic 16 Pages
Current Edition
OMR 46.16
English 9 Pages
Current Edition Reference Language
OMR 30.92

GSO ISO 10313:2014 Scope

1 .l General This International Standard specifies a chemiluminescence method for the determination of the mass concentration of ozone in ambient air. The method is applicable to the determination of the mass concentration of ozone between 2 pg/m3 [O,OOl ppm(V/V)] and 10 mg/m3 [5 ppm(V/V)] at the reference conditions of 25 “C and 101,3 kPa. Ultraviolet (UV) photometry is specified as the primary calibration method because of its proven accuracy and specificity to ozone. The use of transfer Standards is allowed if they have been previously calibrated against the primary calibration method. 1.2 Limitations The chemiluminescent reaction of ozone with ethylene is not subject to interference from any of the common air pollutants. However, particulate matter, if not removed, will accumulate in the sampling line and may Cause a measurable destruction of ozone. If particulate matter is allowed to enter the reaction chamber of the analyser, it will not only scatter the emitted light but will also accumulate on the Optical window, thereby causing further attenuation of the emitted light. Also, any nitrogen(ll) Oxide in the sampled air will to some extent react with the ambient ozone; therefore, the time during which the ambient air remains in the sampling line must be sufficiently short to keep this effect to a minimum. NOTE 1 It has been reported by some researchers that, at about 80 % relative humidity and 22 “C, the responses for some commercially available chemiluminescence analysers were about 10 % higher than that for dry air. However, comparisons of ambient ozone measurements using commercially available chemiluminescence and UV-photometric analysers showed no significant differentes. This suggests that, in practice, any errors associated with calibrations using dry air are compensated by other effects.

Best Sellers From Metrology Sector

OS GSO OIML R87:2021
OIML R87:2016 
Omani Standard
Quantity of product in prepackages
GSO OIML R87:2021
OIML R87:2016 
Gulf Standard
Quantity of product in prepackages
GSO OIML R79:2021
OIML R79:2015 
Gulf Standard
Labeling requirements for prepackages
OS GSO OIML R79:2021
OIML R79:2015 
Omani Standard
Labeling requirements for prepackages

Recently Published from Metrology Sector

GSO ISO 16610-31:2026
ISO 16610-31:2025 
Gulf Standard
Geometrical product specifications (GPS) — Filtration — Part 31: Robust profile filters: Gaussian regression filters
GSO ISO 23783-2:2026
ISO 23783-2:2022 
Gulf Standard
Automated liquid handling systems — Part 2: Measurement procedures for the determination of volumetric performance
GSO ISO 16610-45:2026
ISO 16610-45:2025 
Gulf Standard
Geometrical product specifications (GPS) — Filtration — Part 45: Morphological profile filters: Segmentation
GSO ISO 4064-1:2026
ISO 4064-1:2024 
Gulf Standard
Water meters for cold potable water and hot water — Part 1: Metrological and technical requirements