GSO ISO 10534-1:2013
ISO 10534-1:1996
Gulf Standard
Current Edition
·
Approved on
01 April 2013
Acoustics -- Determination of sound absorption coefficient and impedance in impedance tubes -- Part 1: Method using standing wave ratio
GSO ISO 10534-1:2013 Files
English
20 Pages
Current Edition
Reference Language
OMR
62.51
GSO ISO 10534-1:2013 Scope
1.1 This part of IS0 10534 specifies a method for
the determination of the sound absorption coefficient,
reflection factor and surface impedance or surface
admittance of materials and objects. The values are
determined for normal sound incidence by evaluation
of the standing wave pattern of a plane wave in a
tube, which is generated by the superposition of an
incident sinusoidal plane wave with the plane wave
reflected from the test object.
This method can be used for the determination of the
sound absorption coefficient of sound absorbers for
normal sound incidence. It can further be used for the
determination of the acoustical surface impedance or
surface admittance of sound-absorbing materials. It is
well suited for parameter studies and for the design of
sound absorbers, because only small samples of the
absorber material are needed.
1.2 There are some characteristic differences between
this method and the measurement of sound
absorption in a reverberation room (see IS0 354).
The impedance tube method can be used for the determination
of the reflection factor and also the impedance
or admittance. The sound is incident normally
on the object surface. The reverberation room method
will (under idealized conditions) determine the sound
absorption coefficient for random sound incidence.
The impedance tube method relies on the existence
of a plane incident sound wave and gives exact values
under this condition (measuring and mounting errors
excluded). The evaluation of the sound absorption coefficient
in a reverberation room is based on a number
of simplifying and approximate assumptions concerning
the sound field and the size of the absorber.
Sound absorption coefficients exceeding the value 1
are therefore sometimes obtained.
The impedance tube method requires samples of the
test object which are the size of the cross-sectional
area of the impedance tube. The reverberation room
method requires test objects which are rather large
and can also be applied to test objects with pronounced
structures in the lateral and/or normal directions.
Measurements with such objects in the
impedance tube must be interpreted with care
(see 9.1).
For the computational transformation of the test results
from the impedance tube method (normal incidence)
to the situation of diffuse sound incidence, see
annex D.
I.3 This part of IS0 10534 gives preference to numerical
methods of evaluation instead of graphical
methods, because computers which can perform
these computations are assumed to be available.
Some of the quantities in the formulae are complex.
The arguments of trigonometric functions are in
radians.
Best Sellers From Metrology Sector
OS GSO OIML R87:2021
OIML R87:2016
Omani Standard
Quantity of product in prepackages
GSO OIML R87:2021
OIML R87:2016
Gulf Standard
Quantity of product in prepackages
GSO OIML R79:2021
OIML R79:2015
Gulf Standard
Labeling requirements for prepackages
OS GSO OIML R79:2021
OIML R79:2015
Omani Standard
Labeling requirements for prepackages
Recently Published from Metrology Sector
GSO IEC 61452:2026
IEC 61452:2021
Gulf Standard
Nuclear instrumentation - Measurement of activity or emission rate of gamma-ray emitting radionuclides - Calibration and use of germanium-based spectrometers
GSO ISO 25178-605:2026
ISO 25178-605:2025
Gulf Standard
Geometrical product specifications (GPS) — Surface texture: Areal — Part 605: Design and characteristics of non-contact (point autofocus probe) instruments
GSO ISO 10713:2026
ISO 10713:2025
Gulf Standard
Jewellery and precious metals — Gold alloy coatings
GSO ISO 25178-603:2026
ISO 25178-603:2025
Gulf Standard
Geometrical product specifications (GPS) — Surface texture: Areal — Part 603: Design and characteristics of non-contact (phase shifting interferometry) instruments