GSO ISO 9459-5:2013
ISO 9459-5:2007
Gulf Standard
Current Edition
·
Approved on
01 April 2013
Solar heating -- Domestic water heating systems -- Part 5: System performance characterization by means of whole-system tests and computer simulation
GSO ISO 9459-5:2013 Files
English
35 Pages
Current Edition
Reference Language
OMR
73.39
GSO ISO 9459-5:2013 Scope
This part of ISO 9459 specifies a method for outdoor laboratory testing of solar domestic hot-water (SDHW)
systems. The method may also be applied for in-situ tests, and also for indoor tests by specifying appropriate
draw-off profiles and irradiance profiles for indoor measurements. The system performance is characterized
by means of whole-system tests using a 'black-box' approach, i.e. no measurements on the system
components or inside the system are necessary. Detailed instructions are given on the measurement
procedure, on processing and analysis of the measurement data, and on presentation of the test report.
The theoretical model described in reference [1] is used to characterize SDHW system performance under
transient operation. The identification of the parameters in the theoretical model is carried out by a parameteridentification
software program (see Annex A). The program finds the set of parameters that gives the best fit
between the theoretical model and the measured data.
A wide range of operating conditions shall be covered to ensure accurate determination of the system
parameters. Measured data shall be pre-processed before being used for identification of system parameters.
The identified parameters are used for the prediction of the long-term system performance for the climatic and
load conditions of the desired location, using the same model as for parameter identification. The system
prediction part of the theoretical model requires hourly values of meteorological data (e.g. test reference
years) and specific load data, as described in Annex C.
This part of ISO 9459 can be applied to the following SDHW systems including:
a) systems with forced circulation of fluid in the collector loop;
b) thermosiphon systems;
c) integral collector storage (ICS) systems;.
provided that for b) and c) the validation requirements described in Clause B.2 of Annex B are satisfied.
Systems are limited to the following dimensions1).
⎯ The collector aperture area of the SDHW system is between 1 and 10 m2.
⎯ The storage capacity of the SDHW system is between 50 and 1 000 litres.
⎯ The specific storage-tank volume is between 10 and 200 litres per square metre of collector aperture area.
Limits to the application of this International Standard.
1) This part of ISO 9459 is not intended to establish any safety or health requirements.
2) This part of ISO 9459 is not intended to be used for testing the individual components of the system.
However, it is permitted to obtain test data of components in combination with a test according to the
procedure described here.
3) The test procedure cannot be applied to SDHW systems containing more than one storage tank. This
does not exclude preheat systems with a second tank in series. However, only the first tank is
considered as part of the system being tested.
4) Systems with collectors having non-flat plate-type incident-angle characteristics can be tested if the
irradiance in the data file(s) is multiplied by the measured incident-angle modifier prior to parameter
identification. The same irradiance correction should, in this case, also be used during any
performance predictions based on the identified parameters.
5) The test procedure cannot be applied to SDHW systems with overheating protection devices that
significantly influence the system behaviour under normal operation2).
6) The test procedure cannot be applied to integrated auxiliary solar systems, with a high proportion of
the store heated concurrently by the auxiliary heater. The results of the tests are only valid when the
resulting parameter faux < 0,75.
7) The test procedure cannot be applied to SDHW systems with an external load-side heat exchanger
in combination with a temperature-dependent pump.
Best Sellers From Electrical Sector
GSO 2530:2016
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
OS GSO 2530:2016
GSO 2530:2016
Omani Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
OS GSO 34:2007
GSO 34:2007
Omani Standard
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
GSO 34:2007
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
Recently Published from Electrical Sector
GSO IEC 61643-41:2026
IEC 61643-41:2025
Gulf Standard
Low-voltage surge protective devices - Part 41: Surge protective devices connected to DC low-voltage power systems – Requirements and test methods
GSO IEC 60704-2-3:2026
IEC 60704-2-3:2025
Gulf Standard
Household and similar electrical appliances - Test code for the determination of airborne acoustical noise - Part 2-3: Particular requirements for dishwashers
GSO IEC 60270:2026
IEC 60270:2025
Gulf Standard
High-voltage test techniques – Charge-based measurement of partial discharges
GSO IEC PAS 63629:2026
IEC PAS 63629:2025
Gulf Standard
PSR – Specific rules for luminaires