GSO ISO 9847:2010

ISO 9847:1992
Gulf Standard   Historical · Approved on 31 March 2010

Solar energy - Calibration of field pyranometers by comparison to a reference pyranometer

GSO ISO 9847:2010 Files

Arabic 27 Pages
Historical
71.29 OMR
English 15 Pages
Historical Reference Language
45.07 OMR

GSO ISO 9847:2010 Scope

1.1 This International Standard specifies two preferred methods for the calibration of field pyranometers using reference pyranometers. 1.2 One method, the outdoor calibration or type I, employs solar radiation as the Source, while the other method, the indoor calibration or type II, employs an artificial radiation Source. 1.2.1 The outdoor calibration of field pyranometers may be performed with the pyranometer in a horizontal position (i.e. Zero tilt) (type Ia), in a tilted Position (type Ib), or at normal incidence (type Ic) maintaining the receiver surface perpendicular to the sun’s beam component. 1.2.2 The indoor calibration of field pyranometers may be performed using an integrating sphere with shaded (type Ha) or unshaded (type Hb) lamp(s), or at normal incidence (type HC) frequently using an Optical bench to present the receiver surface perpendicular to the beam of the lamp. Types lla and llb correspond to an outdoor calibration under conditions of overcast and sunny sky with large light cloud fields, respectively. Type Ilc is comparable with the normal incidence calibration of type lc. 1.3 The methods of calibration specified are traceable to the worid radiometric reference (WRR); traceability to the international Pyrheliometric Scale of 1956 is not permitted. 1.4 This International Standard is applicable to most types of field pyranometers regardless of the type of radiation receptor employed. In general, all pyranometers used for lang-term monitoring of incident solar irradiance may be calibrated by using the described methods, provided that the reference pyranorneter has been calibrated at essentially the Same tilt from horizontal as the tilt employed in the calibration. NOTE 1 Pyranometers used for collector tests should be calibrated using a reference pyrheliometer (see ISO 9846).

Best Sellers From Metrology Sector

GSO OIML R87:2021
OIML R87:2016 
Gulf Standard
Quantity of product in prepackages
GSO OIML R79:2021
OIML R79:2015 
Gulf Standard
Labeling requirements for prepackages
OS GSO OIML R76-1:2009
OIML R 76-1:2006 
Omani Standard
Non-automatic weighing instruments – Part 1: Metrological and technical requirements - Tests
GSO OIML R 76-1:2009
OIML R 76-1:2006 
Gulf Standard
Non-automatic weighing instruments – Part 1: Metrological and technical requirements - Tests

Recently Published from Metrology Sector

GSO ISO 80004-1:2024
ISO 80004-1:2023 
Gulf Standard
Nanotechnologies – Vocabulary — Part 1: Core vocabulary
GSO IEC 62055-31:2024
IEC 62055-31:2022 
Gulf Standard
Electricity metering - Payment systems - Part 31: Particular requirements - Static payment meters for active energy (classes 0,5, 1 and 2)
GSO ISO 16399:2024
ISO 16399:2023 
Gulf Standard
Agricultural irrigation equipment — Meters for irrigation water
GSO ISO 8529-3:2024
ISO 8529-3:2023 
Gulf Standard
Neutron reference radiation fields — Part 3: Calibration of area and personal dosemeters and determination of their response as a function of neutron energy and angle of incidence