Workplace atmospheres-Protocol for evaluating the performance of diffusive samplers
GSO ISO 16107:2008 Files
English
15 Pages
Current Edition
Reference Language
OMR
46.16
GSO ISO 16107:2008 Scope
1 Scope
1.1 This International Standard covers the evaluation of the performance of diffusive samplers of gases and
vapours for use over sampling periods from 4 h to 12 h. Sampling periods of such duration are the most common in
workplace sampling. Given a suitable exposure chamber, this International Standard can be straightforwardly
extended to cover samplers for use over other sampling periods as well. The aim is to provide a concise set of
experiments for classifying samplers primarily according to a single numerical value representing sampler accuracy.
NOTE Accuracy estimates refer to conditions of sampler use which are normally expected in a workplace setting. These
conditions may be characterized by the temperature, atmospheric pressure, humidity and ambient wind speed, none of which
may be constant or accurately known. Furthermore, the accuracy accounts for difficulty in the estimation of time-weighted
averages of concentrations which may not be constant in time.
In addition to accuracy determination, a method is provided to test the samplers for compliance with the
manufacturer's stated limits on capacity, possibly in the presence of interfering compounds. A method is given for
classification of samplers according to their capability to detect situations in which sampler capacity may be
exceeded.
1.2 This International Standard is an extension of previous research on diffusive samplers [1-17] as well as EN
838. Essential advantages are the estimation of sampler accuracy under actual conditions of use and the reduction
in cost of sampler evaluation.
NOTE Furthering the latter point, knowledge of similarity between analytes of interest can be used to expedite sampler
evaluation. For example, interpolation of data characterizing the sampling of analytes at separated points of a homologous
series of compounds is recommended. At present the procedure in [9] is suggested: Following evaluation of a sampler in use at
a single homologous series member according to the present practice, higher molecular weight members would receive partial
validations considering sampling rate, capacity, analytical recovery and interferences.
Best Sellers From Chemical and Textile Sector
OS GSO 1943:2024
GSO 1943:2024
Omani Standard
Cosmetic Products – Safety Requirements of Cosmetics and Personal Care Products
GSO 1943:2024
Gulf Technical Regulation
Cosmetic Products – Safety Requirements of Cosmetics and Personal Care Products
GSO 2528:2024
Gulf Technical Regulation
Cosmetic products – Technical Regulation of Cosmetic and Personal Care Products Claims
OS GSO 2528:2024
GSO 2528:2024
Omani Standard
Cosmetic products – Technical Regulation of Cosmetic and Personal Care Products Claims
Recently Published from Chemical and Textile Sector
GSO ASTM E2752:2026
ASTM E2752:25
Gulf Standard
Standard Guide for Evaluation of Residual Effectiveness of Antibacterial Personal Cleansing Products
OS GSO EN 16274:2026
EN 16274:2021
Omani Standard
Method for analysis of allergens - Quantification of an extended list of 57 suspected allergens in ready to inject fragrance materials by gas chromatography mass spectrometry
OS GSO 2815:2026
GSO 2815:2026
Omani Standard
Cosmetic products – Guidelines on labeling requirements of fragrance allergens
OS GSO ASTM E2752:2026
ASTM E2752:25
Omani Standard
Standard Guide for Evaluation of Residual Effectiveness of Antibacterial Personal Cleansing Products