GSO ISO 16107:2008

ISO 16107:1999
Gulf Standard   Current Edition · Approved on 20 February 2008

Workplace atmospheres-Protocol for evaluating the performance of diffusive samplers

GSO ISO 16107:2008 Files

English 15 Pages
Current Edition Reference Language
OMR 46.16

GSO ISO 16107:2008 Scope

1 Scope 1.1 This International Standard covers the evaluation of the performance of diffusive samplers of gases and vapours for use over sampling periods from 4 h to 12 h. Sampling periods of such duration are the most common in workplace sampling. Given a suitable exposure chamber, this International Standard can be straightforwardly extended to cover samplers for use over other sampling periods as well. The aim is to provide a concise set of experiments for classifying samplers primarily according to a single numerical value representing sampler accuracy. NOTE Accuracy estimates refer to conditions of sampler use which are normally expected in a workplace setting. These conditions may be characterized by the temperature, atmospheric pressure, humidity and ambient wind speed, none of which may be constant or accurately known. Furthermore, the accuracy accounts for difficulty in the estimation of time-weighted averages of concentrations which may not be constant in time. In addition to accuracy determination, a method is provided to test the samplers for compliance with the manufacturer's stated limits on capacity, possibly in the presence of interfering compounds. A method is given for classification of samplers according to their capability to detect situations in which sampler capacity may be exceeded. 1.2 This International Standard is an extension of previous research on diffusive samplers [1-17] as well as EN 838. Essential advantages are the estimation of sampler accuracy under actual conditions of use and the reduction in cost of sampler evaluation. NOTE Furthering the latter point, knowledge of similarity between analytes of interest can be used to expedite sampler evaluation. For example, interpolation of data characterizing the sampling of analytes at separated points of a homologous series of compounds is recommended. At present the procedure in [9] is suggested: Following evaluation of a sampler in use at a single homologous series member according to the present practice, higher molecular weight members would receive partial validations considering sampling rate, capacity, analytical recovery and interferences.

Best Sellers From Chemical and Textile Sector

OS GSO 1943:2024
GSO 1943:2024 
Omani Standard
Cosmetic Products – Safety Requirements of Cosmetics and Personal Care Products
GSO 1943:2024
 
Gulf Technical Regulation
Cosmetic Products – Safety Requirements of Cosmetics and Personal Care Products
GSO 2528:2024
 
Gulf Technical Regulation
Cosmetic products – Technical Regulation of Cosmetic and Personal Care Products Claims
OS GSO 2528:2024
GSO 2528:2024 
Omani Standard
Cosmetic products – Technical Regulation of Cosmetic and Personal Care Products Claims

Recently Published from Chemical and Textile Sector

GSO ASTM E2752:2026
ASTM E2752:25 
Gulf Standard
Standard Guide for Evaluation of Residual Effectiveness of Antibacterial Personal Cleansing Products
OS GSO EN 16274:2026
EN 16274:2021 
Omani Standard
Method for analysis of allergens - Quantification of an extended list of 57 suspected allergens in ready to inject fragrance materials by gas chromatography mass spectrometry
OS GSO 2815:2026
GSO 2815:2026 
Omani Standard
Cosmetic products – Guidelines on labeling requirements of fragrance allergens
OS GSO ASTM E2752:2026
ASTM E2752:25 
Omani Standard
Standard Guide for Evaluation of Residual Effectiveness of Antibacterial Personal Cleansing Products