GSO IEC TR 63162:2026
IEC TR 63162:2025
Gulf Standard
Current Edition
·
Approved on
17 September 2026
Electric components - Reliability - Failure rates at reference conditions
GSO IEC TR 63162:2026 Files
English
33 Pages
Current Edition
Reference Language
Obtaining this standard through the store is currently unavailable. You can acquire it directly from its source.
GSO IEC TR 63162:2026 Scope
IEC TR 63162:2025, which is a Technical Specification, provides failure rates at reference conditions for electric components, considering reference conditions defined in IEC 61709.
Reference conditions are useful since they provide a known standard basis from which failure rates can be modified to account for differences in environment from the environments taken as reference conditions.
To perform reliability prediction, which is described in IEC 61709:2017, Annex C, failure rates, together with assumptions and limitations, are used.
IEC 61709 does not provide failure rates for components, but only provides models that allow failure rates obtained by other means to be converted from one operating condition to another operating condition.
This document provides generic failure rates considering those contained in the list of selected sources, calculated at reference conditions, as defined in IEC 61709. In fact, although models are different, calculated values at reference conditions do not appear to be so different, hence allowing a consistent converging process. See also IEC 61709:2017, 4.6.
Each user can easily calculate failure rates at any condition using IEC 61709.
Reference conditions are useful since they provide a known standard basis from which failure rates can be modified to account for differences in environment from the environments taken as reference conditions.
To perform reliability prediction, which is described in IEC 61709:2017, Annex C, failure rates, together with assumptions and limitations, are used.
IEC 61709 does not provide failure rates for components, but only provides models that allow failure rates obtained by other means to be converted from one operating condition to another operating condition.
This document provides generic failure rates considering those contained in the list of selected sources, calculated at reference conditions, as defined in IEC 61709. In fact, although models are different, calculated values at reference conditions do not appear to be so different, hence allowing a consistent converging process. See also IEC 61709:2017, 4.6.
Each user can easily calculate failure rates at any condition using IEC 61709.
Best Sellers From Electrical Sector
GSO 2530:2016
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
OS GSO 2530:2016
GSO 2530:2016
Omani Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
OS GSO 34:2007
GSO 34:2007
Omani Standard
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
GSO 34:2007
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
Recently Published from Electrical Sector
GSO IEC 63522-32:2026
IEC 63522-32:2025
Gulf Standard
Electrical relays - Tests and measurements - Part 32: Acoustic noise
GSO IEC 61362:2026
IEC 61362:2024
Gulf Standard
Guidelines to specification of hydraulic turbine governing systems
GSO IEC TS 62271-313:2026
IEC TS 62271-313:2025
Gulf Standard
High-voltage switchgear and controlgear - Part 313: Direct current circuit-breakers
GSO ISO 20816-21:2026
ISO 20816-21:2025
Gulf Standard
Mechanical vibration — Measurement and evaluation of machine vibration — Part 21: Horizontal axis wind turbines