OS GSO EN 1090-5:2024
EN 1090-5:2017
Omani Standard
Current Edition
·
Approved on
14 October 2024
Execution of steel structures and aluminium structures - Part 5: Technical requirements for cold-formed structural aluminium elements and cold-formed structures for roof, ceiling, floor and wall applications
OS GSO EN 1090-5:2024 Files
No files for this standard are available in the store currently.
Obtaining this standard through the store is currently unavailable. You can acquire it directly from its source.
OS GSO EN 1090-5:2024 Scope
This European Standard specifies requirements for the execution i.e. the manufacture and the installation of cold-formed structural aluminium components made from profiled sheeting for roof, ceiling, floor and wall applications under predominately static loading conditions or seismic loading conditions and their documentation. It does cover products of structural class I and II according to EN 1999-1-4 used in structures.
Structural elements are understood here to mean profiled sheeting, such as trapezoidal, sinusoidal, liner trays or cassette profiles (Figure 1), that are produced by cold forming. Perforated and micro profiled sheeting are also covered by this part.
Welded sections are excluded from this part and are covered by EN 1090-3 except seal welding in low-stress areas.
This standard also covers spacer constructions between the outer and inner or upper and lower skins as well as supporting members for roofs, walls and ceilings made from cold-formed profiled sheeting and the connections and attachments of the afore mentioned elements as long as they are involved in load transfer, it also covers connections and attachments of these elements.
A combination of steel and aluminium structural elements are permitted, e.g. liner trays made of steel, stiffened by profiles made of aluminium. In this case, EN 1090-4 and this document apply.
Composite structural elements where the interaction between dissimilar materials are an integral part of the structural behaviour such as sandwich panels and composite floors are not covered by this standard.
NOTE The structures covered in this standard can be for example
- single- or multi-skin roofs, whereby the load-bearing structure (lower skin) as well as the actual roof covering (upper skin) or both consist of structural elements;
- single- or multi-skin walls whereby the load-bearing structure (inner skin) as well as the actual cladding (outer skin) or both consist of structural elements; or
- suspended ceilings for interior fitting.
Best Sellers From Construction and Building Sector
OS GSO 1431:2002
GSO 1431:2002
Omani Standard
Sanitary appliances - pressurized flushing devices
GSO 1431:2002
Gulf Technical Regulation
Sanitary appliances - pressurized flushing devices
GSO 1427:2008
Gulf Standard
Ceramic Sanitary Appliances - Western Water Closets
OS GSO 1427:2008
GSO 1427:2008
Omani Standard
Ceramic Sanitary Appliances - Western Water Closets
Recently Published from Construction and Building Sector
GSO 113:1989
Gulf Standard
TECHNICAL TERMS AND DEFINITIONS USED
IN SPINNING AND WEAVING INDUSTRY
PART 2: FABRIC DEFECTS
OS GSO 113:1989
GSO 113:1989
Omani Standard
TECHNICAL TERMS AND DEFINITIONS USED
IN SPINNING AND WEAVING INDUSTRY
PART 2: FABRIC DEFECTS
GSO ISO/TS 16774-2:2025
ISO/TS 16774-2:2023
Gulf Standard
Test methods for repair materials for water-leakage cracks in underground concrete structures — Part 2: Test method for chemical resistance
GSO ASTM C1225:2025
ASTM C1225:23
Gulf Standard