OS GSO IEC 62220-2-1:2024
IEC 62220-2-1:2023
Omani Standard
Current Edition
·
Approved on
14 October 2024
Medical electrical equipment - Characteristics of digital X-ray imaging devices - Part 2-1: Determination of dual-energy subtraction efficiency - Detectors used for dual-energy radiographic imaging
OS GSO IEC 62220-2-1:2024 Files
No files for this standard are available in the store currently.
Obtaining this standard through the store is currently unavailable. You can acquire it directly from its source.
OS GSO IEC 62220-2-1:2024 Scope
IEC 62220-2-1:2023 describes the performance metrics associated with DUAL-ENERGY IMAGING capable DIGITAL X-RAY IMAGING DEVICES meant for medical applications and specifies the methods for their determination. These metrics can be used to analyse TISSUE-SUBTRACTED IMAGES and to evaluate dose performance, noise characteristics, and tissue-subtraction efficacy of DIGITAL X-RAY IMAGING DEVICES. The described methods indicate the procedures to obtain MULTI-SPECTRAL PRIMARY DATA and to compute their derived TISSUE-SUBTRACTED IMAGES.
The intended users of this document are MANUFACTURERS and well-equipped test laboratories. This document is restricted to DIGITAL X-RAY IMAGING DEVICES that are used for single or multiple exposure dual-energy radiographic imaging based on, for example, CR systems, direct and indirect flat panel-detector based systems.
This document excludes and is not applicable to:
– DIGITAL X-RAY IMAGING DEVICES intended to be used in mammography or in dental RADIOGRAPHY;
– slot scanning DIGITAL X-RAY IMAGING DEVICES;
– COMPUTED TOMOGRAPHY or CONE-BEAM COMPUTED TOMOGRAPHY;
– photon-energy discriminating devices such as photon counting X-RAY IMAGING DEVICES;
– devices for dynamic imaging (where series of images are acquired, as in fluoroscopy or cardiac imaging).
– DIGITAL X-RAY IMAGING DEVICES intended to be used with RADIOTHERAPY beams.
The intended users of this document are MANUFACTURERS and well-equipped test laboratories. This document is restricted to DIGITAL X-RAY IMAGING DEVICES that are used for single or multiple exposure dual-energy radiographic imaging based on, for example, CR systems, direct and indirect flat panel-detector based systems.
This document excludes and is not applicable to:
– DIGITAL X-RAY IMAGING DEVICES intended to be used in mammography or in dental RADIOGRAPHY;
– slot scanning DIGITAL X-RAY IMAGING DEVICES;
– COMPUTED TOMOGRAPHY or CONE-BEAM COMPUTED TOMOGRAPHY;
– photon-energy discriminating devices such as photon counting X-RAY IMAGING DEVICES;
– devices for dynamic imaging (where series of images are acquired, as in fluoroscopy or cardiac imaging).
– DIGITAL X-RAY IMAGING DEVICES intended to be used with RADIOTHERAPY beams.
Best Sellers From Health Sector
OS GSO 2017:2023
GSO 2017:2023
Omani Standard
Personal Care and Baby Wet Wipes
GSO 2017:2023
Gulf Standard
Personal Care and Baby Wet Wipes
OS GSO 2241:2023
GSO 2241:2023
Omani Standard
Cosmetic Products - Body Cleaners
GSO 2241:2023
Gulf Standard
Cosmetic Products - Body Cleaners
Recently Published from Health Sector
OS GSO ISO 13810:2025
ISO 13810:2022
Omani Standard
Tourism and related services — Visits to industrial, natural, cultural and historical sites — Requirements and recommendations
OS GSO ASTM F3343:2025
ASTM F3343:20(2024)
Omani Standard
Standard Consumer Safety Specification for Infant Bathers
OS GSO ISO/TR 11797:2025
ISO/TR 11797:2024
Omani Standard
Ophthalmic optics – Spectacle lenses – Power and prism measurements
OS GSO EN 13726:2025
EN 13726:2023
Omani Standard
Test methods for wound dressings - Aspects of absorption, moisture vapour transmission, waterproofness and extensibility