OS GSO IEC 60034-18-31:2015

IEC 60034-18-31:2012
Omani Standard   Current Edition · Approved on 03 September 2015

Rotating electrical machines - Part 18-31: Functional evaluation of insulation systems - Test procedures for form-wound windings - Thermal evaluation and classification of insulation systems used in rotating machines

OS GSO IEC 60034-18-31:2015 Files

English 54 Pages
Current Edition Reference Language

OS GSO IEC 60034-18-31:2015 Scope

This part of IEC 60034 describes thermal endurance test procedures for classification of insulation systems used in a.c. or d.c. rotating electrical machines with indirect cooling and form-wound windings. The test performance of a candidate insulation system is compared to the test performance of a reference insulation system with proven service experience. The test procedures described in IEC 60034-18-31 are intended to compare the thermal endurance performance of the mainwall insulation between conductor(s) and ground and,where required by the design of the coil or bar, the insulation between the turns. The test is not intended to simulate the in-service mechanical stresses experienced by the endwinding bracing or support materials. It does not include the evaluation of thermomechanical deterioration by expansion and contraction of insulation during temperature cycling. IEC 60034-18-1 describes general testing principles applicable to thermal endurance testing of insulation systems used in rotating electrical machines. The principles of IEC 60034-18-1 are followed unless otherwise stated in IEC60034-18-31. The thermal class for the insulation system refers to its maximum allowed (“hot spot”) temperature. The average temperature measured in service should not exceed the allowed temperature rise according to IEC 60034-1. NOTE 1 Large machines, especially synchronous generators using bars, may require special thermal evaluation test procedures which are not included in this part. NOTE 2 Recommended parameters for the diagnostic test may be applied according to IEC 60034-18-42 to formwound coils designed with Type II insulation systems for use in converter applications.

Best Sellers From Electrical Sector

GSO 2530:2016
 
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
OS GSO 2530:2016
GSO 2530:2016 
Omani Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
OS GSO 34:2007
GSO 34:2007 
Omani Standard
LEAD-ACID STARTER BATTERIES USED FOR MOTOR VEHICLES AND INTERNAL COMBUSTION ENGINES
GSO 34:2007
 
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR MOTOR VEHICLES AND INTERNAL COMBUSTION ENGINES

Recently Published from Electrical Sector

GSO 2770:2024
 
Gulf Standard
WATER HEATERS - ENERGY PERFORMANCE REQUIREMENTS
GSO IEC TS 62257-4:2024
IEC TS 62257-4:2015 
Gulf Standard
Recommendations for renewable energy and hybrid systems for rural electrification - Part 4: System selection and design
GSO IEC 61968-13:2024
IEC 61968-13:2021 
Gulf Standard
Application integration at electric utilities - System interfaces for distribution management - Part 13: Common distribution power system model profiles
GSO IEC 62246-4:2024
IEC 62246-4:2023 
Gulf Standard
Reed switches – Part 4: Application in conjunction with magnetic actuator used for magnetic sensing devices