OS GSO IEC 61453:2014
IEC 61453:2007
Omani Standard
Current Edition
·
Approved on
25 December 2014
Nuclear instrumentation - Scintillation gamma ray detector systems for the assay of radionuclides - Calibration and routine tests
OS GSO IEC 61453:2014 Files
English
37 Pages
Current Edition
Reference Language
Obtaining this standard through the store is currently unavailable. You can acquire it directly from its source.
OS GSO IEC 61453:2014 Scope
This International Standard specifies methods of calibration and routine tests of scintillation
detector systems for the measurement of gamma-ray energies and emission rates of
radionuclides and the assay of radioactivity.
This International Standard is applicable to scintillation detector systems based on inorganic
scintillators for photon measurements.
Typical applications include radionuclide identification and assay in various industrial,
environmental, and medical applications. The detector system consists of three major
components: a scintillating material that produces photons of light when ionizing radiation
interacts with it; one or more photomultipliers or photodiodes, optically coupled to the
scintillator, which convert the light photons to an amplified electrical pulse or pulses; and
associated electronic instrumentation which powers the photomultiplier and processes the
output signal.
Both energy calibration and efficiency calibration are covered. The following three techniques
are considered:
a) total spectrum counting (see 3.1) which employs a system that counts all pulses above a
low-energy threshold (see 5.1, 5.2 and 5.3);
b) single-channel analyzer (SCA) counting (see 3.2) which employs a system with a counting
channel established through upper and lower energy boundaries (see 5.1, 5.2, and 5.3);
c) multichannel analyzer counting (see 3.3) which employs a system in which multiple
counting windows are utilized. This technique allows measurements for which the
continuum under the total absorption peak may be subtracted without introducing
unacceptable error. In case of overlapping peaks in the spectrum, a multichannel analyzer
(MCA) with access to a peak deconvolution program is necessary. This case is not
covered by this standard.
Best Sellers From Electrical Sector
GSO 2530:2016
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
OS GSO 2530:2016
GSO 2530:2016
Omani Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
OS GSO 34:2007
GSO 34:2007
Omani Standard
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
GSO 34:2007
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
Recently Published from Electrical Sector
GSO IEC 63522-32:2026
IEC 63522-32:2025
Gulf Standard
Electrical relays - Tests and measurements - Part 32: Acoustic noise
GSO IEC TS 62600-301:2026
IEC TS 62600-301:2019
Gulf Standard
Marine energy - Wave, tidal and other water current converters - Part 301: River energy resource assessment
GSO IEC TS 62600-10:2026
IEC TS 62600-10:2021
Gulf Standard
Marine energy - Wave, tidal and other water current converters - Part 10: Assessment of mooring system for marine energy converters (MECs)
GSO IEC 62933-4-2:2026
IEC 62933-4-2:2025
Gulf Standard
Electric energy storage (EES) systems – Part 4-2: Guidance on environmental issues – Assessment of the environmental impact of battery failure in an electrochemical based storage system