OS GSO IEC 60730-2-6:2015

IEC 60730-2-6:2007
Omani Standard   Current Edition · Approved on 09 April 2015

Automatic electrical controls for household and similar use - Part 2-6: Particular requirements for automatic electrical pressure sensing controls including mechanical requirements

OS GSO IEC 60730-2-6:2015 Files

English 49 Pages
Current Edition Reference Language

OS GSO IEC 60730-2-6:2015 Scope

IEC 60730-2-6:2015(E) applies to automatic electrical pressure sensing controls with a minimum gauge pressure rating of -60 kPa and a maximum gauge pressure rating of 4,2 MPa, for use in, on or in association with, equipment. The equipment may use electricity, gas, oil, solid fuel, solar thermal energy, etc. or a combination thereof. This standard is also applicable to individual pressure sensing controls utilized as part of a control system or pressure sensing controls which are mechanically integral with multi-functional controls having non-electrical outputs. Automatic electrical pressure sensing controls for equipment used by the public, such as equipment intended to be used by laymen in shops, in light industry and on farms, are within the scope of this standard. This standard does not apply to pressure sensing controls intended exclusively for industrial process applications unless explicitly mentioned in the relevant equipment standard. This standard applies to inherent safety, operating values, operating sequences where such are associated with equipment protection, and to the testing of automatic electrical pressure sensing controls used in, on or in association with equipment. This standard is also applicable to the functional safety of low complexity safety related pressure sensing controls and systems. This standard is also applicable to pressure sensing controls for appliances within the scope of IEC 60335-1. This third edition cancels and replaces the second edition published in 2007. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - aligns the text with IEC 60730-1, Edition 5; - modifies requirements for Class B control function (H.27.1.2.2); - modifies requirements for Class C control function (H.27.1.2.3) and - modifies requirements for faults during lock-out or safety- shut-down. Key words: sensing controls, control systems, pressure sensing

Best Sellers From Electrical Sector

GSO 2530:2016
 
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
OS GSO 2530:2016
GSO 2530:2016 
Omani Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
OS GSO 34:2007
GSO 34:2007 
Omani Standard
LEAD-ACID STARTER BATTERIES USED FOR MOTOR VEHICLES AND INTERNAL COMBUSTION ENGINES
GSO 34:2007
 
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR MOTOR VEHICLES AND INTERNAL COMBUSTION ENGINES

Recently Published from Electrical Sector

GSO 195:1994
 
Gulf Standard
METHODS OF TEST FOR ADHESIVE INSULATING TAPES FOR ELECTRICAL PURPOSES
GSO 31:1984
 
Gulf Standard
METHODS OF TEST FOR PVC-INSULATED CABLES AND CORDS WITH CIRCULAR COPPER CONDUCTORS
OS GSO 195:1994
GSO 195:1994 
Omani Standard
METHODS OF TEST FOR ADHESIVE INSULATING TAPES FOR ELECTRICAL PURPOSES
OS GSO 158:1993
GSO 158:1993 
Omani Standard
METHODS OF TEST FOR PRESSURE TYPE THERMOSTATS FOR USE IN HOUSEHOLD ELECTRICAL APPLIANCES