OS GSO OIML R83:2008
OIML R 83:2006
Omani Standard
Current Edition
·
Approved on
20 February 2008
Gas chromatograph/mass spectrometer systems for the analysis of organic pollutants in water
OS GSO OIML R83:2008 Files
Arabic
31 Pages
Current Edition
English
24 Pages
Current Edition
Reference Language
Obtaining this standard through the store is currently unavailable. You can acquire it directly from its source.
OS GSO OIML R83:2008 Scope
1.1 This Recommendation provides performance requirements and testing procedures for a gas
chromatograph/mass spectrometer/data (GC/MS) system when used for measurements in determining
water pollutants in pollution control programs and in assessing the quality of water as may be
mandated by national laws and regulations. Several types of mass spectrometers are available which
employ a wide variety of techniques to achieve separation of ions according to mass-to-charge ratios;
however, only low-resolution mass spectrometers are addressed. This Recommendation does not
intend to exclude any other equivalent means of measurement or analysis.
1.2 The mass spectrometers addressed and coupled with appropriate gas chromatographs may be
used successfully to analyze a variety of water samples, such as ground waters, surface waters,
aqueous municipal and industrial effluents, and saline waters. A sample may require specific
preparation techniques prior to analysis by a GC/MS system. Although important to an overall
analysis, considerations of sampling, sample preparation, and pollutant measurement methods are
beyond the scope of this Recommendation.
1.3 Pollutant compounds of interest in a sample may be analyzed by a GC/MS system if they are
present in detectable amounts, can pass through the gas chromatographic column, and are not
significantly affected by thermal or catalytic decomposition or adsorption. Some compounds that are
difficult to analyze, such as those that are non-volatile or thermally unstable, can be converted to
derivative compounds that then may undergo gas chromatographic separation and detection by the
mass spectrometer.
1.4 Performance criteria better than those prescribed in this Recommendation for these
applications of a GC/MS system may be achieved by paying careful attention to optimizing the
performance of each component of the measurement system. In such cases, success depends on the
knowledge, skill, and experience of the analyst.
Best Sellers From Metrology Sector
OS GSO OIML R87:2021
OIML R87:2016
Omani Standard
Quantity of product in prepackages
GSO OIML R87:2021
OIML R87:2016
Gulf Standard
Quantity of product in prepackages
GSO OIML R79:2021
OIML R79:2015
Gulf Standard
Labeling requirements for prepackages
OS GSO OIML R79:2021
OIML R79:2015
Omani Standard
Labeling requirements for prepackages
Recently Published from Metrology Sector
GSO IEC 61452:2026
IEC 61452:2021
Gulf Standard
Nuclear instrumentation - Measurement of activity or emission rate of gamma-ray emitting radionuclides - Calibration and use of germanium-based spectrometers
GSO ISO 25178-605:2026
ISO 25178-605:2025
Gulf Standard
Geometrical product specifications (GPS) — Surface texture: Areal — Part 605: Design and characteristics of non-contact (point autofocus probe) instruments
GSO ISO 10713:2026
ISO 10713:2025
Gulf Standard
Jewellery and precious metals — Gold alloy coatings
GSO ISO 25178-603:2026
ISO 25178-603:2025
Gulf Standard
Geometrical product specifications (GPS) — Surface texture: Areal — Part 603: Design and characteristics of non-contact (phase shifting interferometry) instruments