ISO 5725-3:2023

مواصفة قياسية دولية   الإصدار الحالي · اعتمدت بتاريخ ٢٨ يونيو ٢٠٢٣

Accuracy (trueness and precision) of measurement methods and results — Part 3: Intermediate precision and alternative designs for collaborative studies

ملفات الوثيقة ISO 5725-3:2023

الإنجليزية 57 صفحات
الإصدار الحالي
86.47 OMR

مجال الوثيقة ISO 5725-3:2023

This document provides

a)    a discussion of alternative experimental designs for the determination of trueness and precision measures including reproducibility, repeatability and selected measures of intermediate precision of a standard measurement method, including a review of the circumstances in which their use is necessary or beneficial, and guidance as to the interpretation and application of the resulting estimates, and

b)    worked examples including specific designs and computations.

Each of the alternative designs discussed in this document is intended to address one (or several) of the following issues:

a)    a discussion of the implications of the definitions of intermediate precision measures;

b)    a guidance on the interpretation and application of the estimates of intermediate precision measures in practical situations;

c)    determining reproducibility, repeatability and selected measures of intermediate precision;

d)    improved determination of reproducibility and other measures of precision;

e)    improving the estimate of the sample mean;

f)     determining the range of in-house repeatability standard deviations;

g)    determining other precision components such as operator variability;

h)    determining the level of reliability of precision estimates;

i)     reducing the minimum number of participating laboratories by optimizing the reliability of precision estimates;

j)     avoiding distorted estimations of repeatability (split-level designs);

k)    avoiding distorted estimations of reproducibility (taking the heterogeneity of the material into consideration).

Often, the performance of the method whose precision is being evaluated in a collaborative study will have previously been assessed in a single-laboratory validation study conducted by the laboratory which developed it. Relevant factors for the determination of intermediary precision will have been identified in this prior single-laboratory study.

الأكثر مبيعاً

GSO 150-2:2013
 
مواصفة قياسية خليجية
فترات صلاحية المنتجات الغذائية - الجزء الثاني : فترات الصلاحية الاختيارية
OS GSO 150-2:2013
GSO 150-2:2013 
مواصفة قياسية عمانية
فترات صلاحية المنتجات الغذائية - الجزء الثاني : فترات الصلاحية الاختيارية
OS GSO 2055-1:2015
GSO 2055-1:2015 
مواصفة قياسية عمانية
الأغذية الحلال – الجزء الأول : الاشتراطات العامة للأغذية الحلال
GSO 2055-1:2015
 
لائحة فنية خليجية
الأغذية الحلال – الجزء الأول : الاشتراطات العامة للأغذية الحلال

اعتمدت مؤخراً

ISO 7718-2:2025
 
مواصفة قياسية دولية
Aircraft — Passenger doors interface requirements for connection of passenger boarding bridge or passenger transfer vehicle — Part 2: Upper deck doors
ISO/IEC/IEEE 32430:2025
 
مواصفة قياسية دولية
Software engineering — Software non-functional size measurement
ISO 10218-1:2025
 
مواصفة قياسية دولية
Robotics — Safety requirements — Part 1: Industrial robots
ISO 10218-2:2025
 
مواصفة قياسية دولية
Robotics — Safety requirements — Part 2: Industrial robot applications and robot cells