ISO 11140-6:2022

مواصفة قياسية دولية   الإصدار الحالي · اعتمدت بتاريخ ٢٢ نوفمبر ٢٠٢٢

Sterilization of health care products — Chemical indicators — Part 6: Type 2 indicators and process challenge devices for use in performance testing of small steam sterilizers

ملفات الوثيقة ISO 11140-6:2022

الإنجليزية 40 صفحات
الإصدار الحالي
OMR 88.44

مجال الوثيقة ISO 11140-6:2022

This document specifies the performance requirements and test methods for hollow devices and porous devices as well as the chemical indicators and biological indicators that are utilized within these devices for testing a specific steam penetration performance of type B cycles and some type S cycles of small steam sterilizers according to EN 13060.

NOTE      The hollow and porous devices described in this document are not intended for use as surrogate devices for hollow and porous medical devices used in health care facilities.

a)    Chemical indicators used with a porous device specified in this document are designed to demonstrate the adequacy of steam penetration into a porous device in small steam sterilizers (see EN 13060).

This document specifies the requirements for:

    a reference porous device (RPD) as a reference device by which alternative porous indicator systems (APISs) can be shown to be equivalent in performance according to this document, i.e. a textile test pack in which steam penetration is judged by thermometric means;

    an alternative porous chemical indicator system equivalent in performance to the RPD, i.e. an APIS, usually commercially manufactured, of any design.

b)    Chemical indicators used with a hollow load device specified in this document are designed to demonstrate the adequacy of steam penetration into a narrow lumen (previously known as hollow load A) in small steam sterilizers (see EN 13060).

This document specifies the requirements for:

    a reference hollow device (RHD) used as a reference device in this document, i.e. a lumened device with attached capsule in which steam penetration is judged by inactivation or survival of a specified biological indicator;

    an alternative hollow device:

    employing the same specific test load as defined for the RHD and a chemical indicator designed specifically for use in the reference hollow test load, i.e. a lumened device with an attached capsule in which steam penetration is judged by visual examination of a chemical indicator;

    equivalent in performance to the RHD, i.e. an alternative hollow device, usually commercially manufactured, of any design.

الأكثر مبيعاً

GSO 150-2:2013
 
مواصفة قياسية خليجية
فترات صلاحية المنتجات الغذائية - الجزء الثاني : فترات الصلاحية الاختيارية
OS GSO 150-2:2013
GSO 150-2:2013 
مواصفة قياسية عمانية
فترات صلاحية المنتجات الغذائية - الجزء الثاني : فترات الصلاحية الاختيارية
OS GSO 9:2022
GSO 9:2022 
مواصفة قياسية عمانية
بطاقات المواد الغذائية المعبأة
GSO 9:2022
 
لائحة فنية خليجية
بطاقات المواد الغذائية المعبأة

اعتمدت مؤخراً

ISO/TR 13849-3:2026
 
مواصفة قياسية دولية
Safety of machinery — Safety-related parts of control systems — Part 3: Markov model-based PFH calculation
ISO/TS 23099:2026
 
مواصفة قياسية دولية
Large yachts — A methodologic framework to assess large yachts (30m+) on their environmental performance and credentials
ISO 11783-3:2026
 
مواصفة قياسية دولية
Tractors and machinery for agriculture and forestry — Serial control and communications data network — Part 3: Application layer, transport layer and network layer
ISO 13914:2026
 
مواصفة قياسية دولية
Soil, treated biowaste and sludge — Determination of dioxins and furans and dioxin-like polychlorinated biphenyls by gas chromatography with mass selective detection (high resolution mass spectrometry, HRMS, and tandem mass spectrometry, MS/MS)