GSO ISO 14708-2:2024

ISO 14708-2:2019
Gulf Standard   Current Edition · Approved on 25 April 2024

Implants for surgery — Active implantable medical devices — Part 2: Cardiac pacemakers

GSO ISO 14708-2:2024 Files

English 71 Pages
Current Edition Reference Language
96.26 OMR

GSO ISO 14708-2:2024 Scope

This document specifies requirements that are applicable to those active implantable medical devices intended to treat bradyarrhythmias and devices that provide therapies for cardiac resynchronization.

The tests that are specified in this document are type tests, and are to be carried out on samples of a device to show compliance.

This document was designed for bradyarrhythmia pulse generators used with endocardial leads or epicardial leads. At the time of this edition, the authors recognized the emergence of leadless technologies for which adaptations of this part will be required. Such adaptations are left to the discretion of manufacturers incorporating these technologies.

This document is also applicable to some non-implantable parts and accessories of the devices (see Note 1).

The electrical characteristics of the implantable pulse generator or lead are determined either by the appropriate method detailed in this particular standard or by any other method demonstrated to have an accuracy equal to, or better than, the method specified. In case of dispute, the method detailed in this particular standard applies.

Any features of an active implantable medical device intended to treat tachyarrhythmias are covered by ISO 14708-6.

NOTE 1 The device that is commonly referred to as an active implantable medical device can in fact be a single device, a combination of devices, or a combination of a device or devices and one or more accessories. Not all of these parts are required to be either partially or totally implantable, but there is a need to specify some requirements of non-implantable parts and accessories if they could affect the safety or performance of the implantable device.

NOTE 2 In this document, terms printed in italics are used as defined in Clause 3. Where a defined term is used as a qualifier in another term, it is not printed in italics unless the concept thus qualified is also defined.

Best Sellers From Health Sector

OS GSO 2017:2023
GSO 2017:2023 
Omani Standard
Personal Care and Baby Wet Wipes
GSO 2017:2023
 
Gulf Standard
Personal Care and Baby Wet Wipes
OS GSO 2241:2023
GSO 2241:2023 
Omani Standard
Cosmetic Products - Body Cleaners
GSO 2241:2023
 
Gulf Standard
Cosmetic Products - Body Cleaners

Recently Published from Health Sector

GSO ISO 1797:2025
ISO 1797:2017 
Gulf Standard
Dentistry — Shanks for rotary and oscillating instruments
GSO ISO 16571:2025
ISO 16571:2024 
Gulf Standard
Systems for evacuation of plume generated by medical devices
GSO ISO 20611:2025
ISO 20611:2018 
Gulf Standard
Adventure tourism — Good practices for sustainability — Requirements and recommendations
GSO ISO 7787-2:2025
ISO 7787-2:2020 
Gulf Standard
Dentistry — Laboratory cutters — Part 2: Carbide laboratory cutters