OS GSO IEC 60364-5-56:2010

IEC 60364-5-56:2009
Omani Standard   Current Edition · Approved on 31 October 2010

Low-voltage electrical installations - Part 5-56: Selection and erection of electrical equipment - Safety services

OS GSO IEC 60364-5-56:2010 Files

English 38 Pages
Current Edition Reference Language

OS GSO IEC 60364-5-56:2010 Scope

IEC 60364-5-56:2009 covers general requirements for safety services, selection and erection of electrical supply systems for safety services and electrical safety sources. Standby electrical supply systems are outside the scope of this part. This part does not apply to installations in hazardous areas (BE3), for which requirements are given in IEC 60079-14. This second edition of IEC 60364-5-56 comes about as a result of changes to Clause 556, Safety services, of IEC 60364-5-55 (2001), as modified by its amendment 1 (2001). It replaces Clause 556 of IEC 60364-5-55:2001. Clause 556 is to be withdrawn at the time of publication of this new Part 56. The main changes with regard to the previous edition are listed below: 1) Many more definitions are included, e.g. response time, central power supply system, low power supply system, preferential circuit and escape route. 2) Automatic supplies are now classified according to the maximum changeover times, for example a supply classified as short break means an automatic supply is available within 0,5 s. 3) Safety sources that can operate in parallel are specifically recognized in 560.6.9. 4) Requirements are now given for batteries used for safety sources for central and low power supply sources. 5) Drawings are now required, such as a single-line diagram, drawings showing the location of equipment and a list of equipment permanently connected to the safety power supply. 6) Operating instructions are now required. 7) Detailed requirements are now given for emergency escape lighting applications, direct current circuits and fire protection applications. 8) Additional requirements for initial verification and periodic inspection and testing are now included in the standard. 9) Two annexes are now included (Annex A and Annex B) giving guidance for emergency lighting and guidance for fire protection equipment, respectively.

Best Sellers From Electrical Sector

GSO 2530:2016
 
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
OS GSO 2530:2016
GSO 2530:2016 
Omani Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
OS GSO 34:2007
GSO 34:2007 
Omani Standard
LEAD-ACID STARTER BATTERIES USED FOR MOTOR VEHICLES AND INTERNAL COMBUSTION ENGINES
GSO 34:2007
 
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR MOTOR VEHICLES AND INTERNAL COMBUSTION ENGINES

Recently Published from Electrical Sector

GSO IEC 63522-32:2026
IEC 63522-32:2025 
Gulf Standard
Electrical relays - Tests and measurements - Part 32: Acoustic noise
GSO IEC TS 62600-301:2026
IEC TS 62600-301:2019 
Gulf Standard
Marine energy - Wave, tidal and other water current converters - Part 301: River energy resource assessment
GSO IEC TS 62600-10:2026
IEC TS 62600-10:2021 
Gulf Standard
Marine energy - Wave, tidal and other water current converters - Part 10: Assessment of mooring system for marine energy converters (MECs)
GSO IEC 62933-4-2:2026
IEC 62933-4-2:2025 
Gulf Standard
Electric energy storage (EES) systems – Part 4-2: Guidance on environmental issues – Assessment of the environmental impact of battery failure in an electrochemical based storage system